Dacor Preference SGM304 Planning Manual - Sgm304, Sgm365, Sgm466
PLANNING
GUIDE
4.8
Specifications subject to change without notice.
Phone: (800) 793-0093
www.Dacor.com
SGM304, SGM365, SGM466
Cutout tolerances +1/16” (+1.6 mm), -0, unless otherwise noted
Countertop Dimensions
installation Type
Cutout
Diagram
(C) Min.
(D)
(E)
(F)
(g)
(H)
SGM304
without raised vent
Figure 1
(Square)
2 7/8”
(7.3 cm)
19 3/4”
(50.2 cm)
27 3/4”
(68.6 cm)
NA
NA
NA
SGM304
with ERV30 or PRV30
Figure 1
(Square)
3/8”
(1.0 cm)
22 1/2” *
(57.2 cm)
27 3/4”
(68.6 cm)
NA
NA
NA
SGM304
with RV30
Figure 1
(Square)
5/8”
(1.6 cm)
22 1/4” *
(56.5 cm)
27 3/4”
(68.6 cm)
NA
NA
NA
SGM365
without raised vent
Figure 1
(Square)
2 7/8”
(7.3 cm)
19 3/4”
(50.2 cm)
33 5/8”
(85.4 cm)
NA
NA
NA
SGM365
with ERV36 or PRV36
Figure 1
(Square)
3/8”
(1.0 cm)
22 1/2” *
(57.2 cm)
33 5/8”
(85.4 cm)
NA
NA
NA
SGM365
with RV36
Figure 1
(Square)
5/8”
(1.6 cm)
22 1/4” *
(56.5 cm)
33 5/8”
(85.4 cm)
NA
NA
NA
SGM466
without raised vent
Figure 1
(Square)
2 7/8”
(7.3 cm)
19 3/4”
(50.2 cm)
44 3/4”
(113.7 cm)
NA
NA
NA
SGM466
with PRV46
Figure 2
(Notched)
3/8”
(1.0 cm)
22 1/2” *
(57.2 cm)
44 3/4”
(113.7 cm)
43 1/2”
(110.5 cm)
5/8”
(1.6 cm)
2 5/8” **
(6.7 cm)
SGM466
with RV46
Figure 2
(Notched)
5/8”
(1.6 cm)
22 1/4” *
(56.5 cm)
44 3/4”
(113.7 cm)
43 1/2”
(110.5 cm)
5/8”
(1.6 cm)
2 5/8” **
(6.7 cm)
Stiffener
Cabinet face
Countertop
Floor
3/8” min. (1.0 cm) space
behind raised vent
chassis to clear stiffener
3/8” min. (1.0 cm)
flat countertop overhang
required behind cutout
ERV or PRV series raised
vent: Check raised vent
dimensions/specifications
to determine proper fit
SGM series cooktop
Stiffener
Cabinet face
Countertop
Floor
5/8” min. (1.6 cm) space
behind raised vent
chassis to clear stiffener
4 5/8” (11.7 cm)
9 7/8” (25.1 cm) with
CABP3 blower installed
5/8” min. (1.6 cm)
flat countertop overhang
required behind cutout
RV series raised vent:
Check raised vent
dimensions/specifications
to determine proper fit
SGM series cooktop
Cutout Dimensions
SIDE VIEW - SGM SErIES CooktoP WIth
ErV or PrV SErIES rAISED VENt
SIDE VIEW - SGM SErIES CooktoP WIth
rV SErIES rAISED VENt
iMPOrTanT:
Be careful to use the correct cutout diagram (on page 5/5) to determine the countertop dimensions for the installation type. Carefully double
check all dimensions against the table below and the correct diagram before cutting the countertop.
* Total cutout depth, accommodates both the cooktop and raised vent
**
iMPOrTanT:
Notch depth is included in total cutout depth (D).
DO nOT
add notch depth to total cutout depth (D).
Document # PG04-004
Revised 01/27/11 Page 4/5
30”, 36”, 46” Wide,
Gas Cooktops