Daewoo DSB-181LH Service Manual - Cooling Airflow Prevention
16
Cooling Airflow Prevention
When the indoor coil temperature is lower than 30°C, Microcomputer of the unit stops indoor fan to prevent cooling
airflow.
Heating Airflow Prevention
When the indoor coil temperature is higher than 65°C, Microcomputer of the unit stops the compressor to prevent it
from overheating. In the funcfion of HEATING AIRFLOW PREVENTION, when pressing FAN SPEED button,
Remote controller received the signal, but the unit don’t operate.
After resetting the function of HEATING AIRFLOW PREVENTION, the unit operate by receiving the signal.
Defrost Airflow Prevention
In HEAT mode, the defrost is performed in the following conditions
–When the outdoor coil temperature is less than or equal to -5°C
–The compressor run time is greater than 50 minutes.
(2) Heating Condition (Room Temperature 22°C)
!
Fan Speed: Super high speed
@
Air discharge direction: Fixed
#
Set temperature: 32°C (Fixed)
$
Operation Mode: Heating Mode
%
Compressor and Outdoor Fan
-1
OFF
ON
(Room temperature-32˚C)
0
1
<