Daewoo DWA-122R Use & Care Manual

Other manuals for DWA-122R: Service Manual, Service Manual, Use & Care Manual

Summary of DWA-122R

  • Page 1

    1 please observe the following instructions. 1. Operate the selector switch to run or stop the unit. - do not use main power switch or auxiliary power switch to operate unit. 2. Do not stick anything into the air outlet or inlet. - it is dangerous and it can cause injury or damage. 3. Avoid exposing...

  • Page 2: Table of Contents

    2 1. General specifications ....................................................................................................................2 2. Installation instructions...........................................................................................................3~9 • window requir...

  • Page 3: Installation Instructions

    3 installation instructions • window requirements these instructions are provided for a standard double hung window or mobile home double hung window installation in windows 27.5 inch (699mm) to 36 in (914mm). The upper and lower sash must open sufficiently to allow a clear vertical opening of 15 in...

  • Page 4

    4 • safety instructions (continued) the receptacle should be an individual branch circuit used only for this air conditioner. Be sure the electrical service is adequate for the model air conditioner you have chosen. The complete electrical rating of your air conditioner is stated on the name plate l...

  • Page 5

    5 • step 1 - prepare components for installation parts for installation are as follows; • sill bracket (2 pieces) • window kit left side (frame ‘l+shutter) - (1 piece) • window kit right side (frame ‘r+shutter) - (1 piece) • sash bracket (1 piece) • drain, drain seal • frame guide lower - (2 pieces)...

  • Page 6

    6 3. Disassemble front grille from chassis. – front grille and chassis are fixed with snap-fit. 1) release right-lower snap-fit. – push the right lower side of chassis to the left, with pushing left side of front grille to the right until the snap-fit is released. 2) release left-lower snap-fit. – p...

  • Page 7

    7 4. Reinstall the unit, side screws, front grille. Caution • when the front grille is reinstalled, the door vent should be in position first so that it would not be bent by grille. Door vent.

  • Page 8

    8 • step 4 - placing chassis 1. Insert narrow side of ‘frame guide lower’ to rectangle holes located in bottom of chassis, and fasten it with screw (type e). 2. Insert window kit frames to top guide and lower guide. 3. Fasten shutter to side holes of chassis with six screws (type e). 4. Place the ch...

  • Page 9

    • step 6 - recheck installation to be sure you have correctly installed your room air conditioner, review the steps and make sure all of the parts are securely fastened in the window as the instructions show. A tight seal is essential. Read through the use & care manual to become familiar with the o...

  • Page 10: Names of Major Components

    10 no part name 1 air filter 2 grille front 3 cabinet 4 blade vertical 5 panel control 6 remote controller no part name 7 blade horizental 8 air vent 9 frame guide top 10 frame window kit 11 shutter window names of major components 6 9 3 2 0 7 q 4 8 5 3 2 7 4 8 5 1 1.

  • Page 11: Operation Instructions

    11 • display operation instructions mode fan speed auto swing power room air-conditioner fan turbo cooling room temp desired temp timer temp sensor temp./timer display • it displays the temperature and the timer. Mode display • it displays the operating mode. Remote signal receiver temperature set •...

  • Page 12

    12 • remote control remote signal transmitter timer/cancel • everytime you push this button, timer is set as follow. (1hr → 2hr → 3hr → 4hr → 5hr → 6hr → 8hr → 10hr → 12hr → 16hr → 20hr → 24hr → cancel). After the unit is timed, if this button is pushed, timer is canceled. Sleep • sleep mode is sele...

  • Page 13

    13 function power on push power button cooling mode push the ‘mode’ button until ‘cooling’ lamp lights. Change desired room temperature push the ‘temp ▲▼ ’ button. Change ‘fan speed’ push the ‘fan speed’ button. Operation 1. The unit starts working. (it is delayed 3 minutes after main power source i...

  • Page 14

    14 function fan mode push the ‘mode’ button until ‘fan’ lamp lights. On/off auto swing push the ‘auto swing’ button. Turbo mode push the ‘mode’ button until ‘turbo’ lamp lights. Off timer push the ‘timer/cancel’ button when unit is working. (remocon only) operation 1. The fan works only. 2. In this ...

  • Page 15

    15 function on timer push the ‘timer/cancel’ button when unit is off. (remocon only) sleep mode push the ‘sleep’ button in ‘cooling’ mode. (remocon only) operation 1. Timer is changed to as follows by pushing “timer/cancel” button. (1hr → 2hr → 3hr → 4hr → 5hr → 6hr → 8hr → 10hr → 12hr → 16hr → 20hr...

  • Page 16

    16 • how to insert batteries remove the cover from the back of the remote controller. • slide the cover according to the arrow direction insert two batteries. • be sure that the (+) and (–) directions are correct • be sure that both batteries are new re-attach the cover. • slide it back into positio...

  • Page 17: General Information

    17 • air flow around unit check in door grill and outdoor louvers for air flow obstructions. Do not block air flow to and from unit. The outdoor coil should be checked and periodically cleaned for debris that may collect and block unit air flow. If air flow is obstructed or deflected back into unit,...

  • Page 18: Care and Maintenance

    18 • air filter clean the air filter, which removes dust inside the room. It should be washed at least once every week during operation. 1. Remove the air filter from the front grill by pulling to right. 2. Clean air filter with a vacuum cleaner or lukewarm, soapy water. 3. Shake it when clean to re...

  • Page 19: Electrical Requirements

    19 • electrical grounding instructions this appliance is equipped with a three-prong(grounding) plug for protection against possible shock hazards. If a two-prong wall receptacle is encountered, the customer is required to contact a qualified electrician and have the two-prong wall receptacle replac...

  • Page 20: Before Calling For Service

    20 before calling for service when you find something wrong with your room air conditioner, please carefully check the following items. If you are unable to find the cause of trouble, contact your service dealer. Difficulty • air conditioner does not operate. • little or no cooling • noisy unit • or...

  • Page 21: Limited Warranty

    Limited warranty daewoo electronics america, inc. Warrants the following window room air- conditioner to be free from defective material and workmanship and agrees to remedy any such defect or to furnish a new part (at the company’s option) in exchange for any part of any unit of its manufacture whi...

  • Page 22: Room Air Conditioner

    Model #: dwc-100r dwc-121r dwa-122r dwa-150r dwa-151r room air conditioner use & care manual window type room air conditioner please read carefully and thoroughly this manual before operating the unit. If you still have any difficulties or problems, consult your dealer for help or electronics. Pleas...