E.T. Systems Challenger MKIII Installer Manual - Programming & Commissioning
21
3.
Press and release the button on the PCB or use the transmitter which
has been pre-programmed in PROGRAMMING THE TRANSMITTER INTO
THE ONBOARD RECEIVER (FIg 18.2). The door will start closing.
4.
When the door reaches the closed position, use the PCB button or the
TX to stop the door.
5.
Slide the limit magnetic
assembly situated on the chain
into position above the switch
assembly on the chassis of unit.
6.
Press and release the button
on the PCB or use the transmit-
ter which has been pre-pro-
grammed in PROGRAMMING THE
TRANSMITTER INTO THE ONBOARD RECEIVER. The door will start opening.
7.
When the door reaches the open position, use the PCB button or the
TX to stop the door.
8.
Slide the limit magnetic
assembly situated on the chain into
position above the switch assembly on
the chassis of unit.
9.
Test the positions of the limits:
Press the PCB button or TX. The
operator should run to the close and
open positions and stop on the limits.
If not correct, move the limit until the
correct position has been reached.
10.
When satisfied, secure the
magnetic limit assemblies, using the
3 mm x16 mm counter sunk self
tapping screws.
Load profile and run-time can now be
programmed.
PROGRAMMING & COMMISSIONING
Figure 21.3
Figure 21.1
Figure 21.2