    User’s manual versions commencing november 2001 a$12.00 inc gst e-tech et8 control panel v4 – user’s manual, revision 1 e - t e c h e t 8 a l a r m c o n t r o l p a n e l a n d d i a l l e r.

  • Page 2

    “australia’s largest designer and manufacturer of high quality security products” e-tech security products pty ltd quality endorsed fictional company iso9001 lic.No. Qec2074 nsw head office only head office: e-tech security products pty ltd abn 000 110 110 12 security close safe hills nsw 2147 austr...

  • Page 3

    Contents features ...................................................................... 4 introduction ................................................................. 5 keypad ........................................................................ 6 keypad indicators ...............................

  • Page 4

    E-tech et8 v4 control panel - user manual 4 • 8 fully programmable zones • any combination of hardwire or radio zones • full radio supervision • contact id dialler format • ultra-modern and impact resistant housing • e-tech audible dialler format • "follow me" audible dialler option • separate 24 ho...

  • Page 5

    E-tech et8 v4 control panel - user manual 5 introduction the e-tech et8 micro computer based 8 zone control panel is the heart of your security system to which all your detection devices connect. Each zone of the panel can be connected to one or more detection devices to protect separate rooms of yo...

  • Page 6

    E-tech et8 v4 control panel - user manual 6 keypad the et8 control panel may be supplied with either the led keypad (100-192) or the e-tech lcd keypad (100-667). The keypad provides important visual and audible indications and is the main interface for operating and programming the et8 control panel...

  • Page 7

    E-tech et8 v4 control panel - user manual 7 keypad indicators zone is sealed zone is unsealed, or power fault or system is armed, or phone line fault disarmed disarmed disarmed normal normal normal normal normal normal normal normal ready to arm zone is unsealed ready to arm armed (area 1) armed (ar...

  • Page 8

    E-tech et8 v4 control panel - user manual 8 operation this section describes the operation of a typical control panel installation. Keep in mind that your installation may vary depending on the selected options and equipment. The operating instructions which follow will cover the most common options...

  • Page 9

    E-tech et8 v4 control panel - user manual 9 operation the control panel must be armed prior to vacating the premises in order to detect intruders. Ensure that the panel is not in program, memory or exclude modes. Note: if the panel is already in alarm, you must first silence the alarm before you can...

  • Page 10

    E-tech et8 v4 control panel - user manual 10 when you enter the protected premises through a delay zone, the keypad responds with regular beeps* as a reminder to disarm. You then have your programmed entry delay time to disarm the panel by entering one of your user codes. If the panel is not disarme...

  • Page 11

    E-tech et8 v4 control panel - user manual 11 operation monitor mode allows you to arm selected zones while others are ignored. Typically, perimeter zones (doors and windows) can be monitored while you are at home. Your installer must program which zones will be active in monitor mode. The panel must...

  • Page 12

    E-tech et8 v4 control panel - user manual 12 the keypad panic function may have been programmed to be either audible - activates siren or buzzers, or silent - if your system is monitored by a central station, sends a panic report by dialler. (if panic reports have been enabled by your installer). Op...

  • Page 13

    E-tech et8 v4 control panel - user manual 13 1. If keypad fire alarm has been enabled by your installer 1. If keypad fire alarm has been enabled by your installer 2. If fire alarm report has been enabled by your installer 2. If fire alarm report has been enabled by your installer 1. If your system i...

  • Page 14

    E-tech et8 v4 control panel - user manual 14 operation if a detector becomes faulty and cannot be sealed when arming the panel, then its zone may be excluded so that it does not generate alarms. When zones have been excluded, the exclude light flashes continuously while the panel is disarmed and als...

  • Page 15

    E-tech et8 v4 control panel - user manual 15 operation the et8 control panel stores a comprehensive alarm memory, including arming, disarming, low battery, mains fail and alarm events. The memory is constantly upgraded and the last 30 events are always available for viewing. This memory display can ...

  • Page 16

    E-tech et8 v4 control panel - user manual 16 radio key operation e-tech radio key 3 button the optional e-tech radio key allows you to arm, disarm and activate panic. The radio key can also arm monitor mode, (if this has been enabled by your installer). Arming press the on button. • the keypad will ...

  • Page 17

    E-tech et8 v4 control panel - user manual 17 option option no programmed range factory default user code 1 (master code) p11e 123 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 ...

  • Page 18

    E-tech et8 v4 control panel - user manual 18 programming enters program mode. The program light will be on. Enters program mode. The program light will be on. The two digit option number for the code to be programmed. The existing code (if any) will be displayed. The existing code (if any) will be d...

  • Page 19

    E-tech et8 v4 control panel - user manual 19 programming enters program mode. The program light will be on. Enters program mode. The program light will be on. The existing telephone number (if any) will be displayed. The existing telephone number (if any) will be displayed. The new telephone number ...

  • Page 20

    E-tech et8 v4 control panel - user manual 20 monitoring central station monitoring the et8 control panel has an on-board digital dialler which can send detailed alarm messages to a central monitoring station. The digital messages can include information about the zone or zones which caused the alarm...

  • Page 21

    E-tech et8 v4 control panel - user manual 21 * the primary and secondary telephone numbers are normally only used for central station monitoring. These numbers can only be programmed in installer program mode. ** the follow me telephone number replaces the primary and secondary telephone numbers. Mo...

  • Page 22

    E-tech et8 v4 control panel - user manual 22 operating the et8 by telephone the et8 will allow a user to call in to the panel, using a standard dtmf telephone, and remotely arm or disarm all areas and also turn on or off aux 1 and aux 2. To ensure security of operation a user can only carry out remo...

  • Page 23

    E-tech et8 v4 control panel - user manual 23 remote operation example: arming the et8 by telephone 1. Dial the et8 telephone number. Listen for one double ring then hang up. 2. Wait 10 seconds, then dial the et8 telephone number again. The et8 will answer immediately and gives a 2 second beep follow...

  • Page 24

    E-tech et8 v4 control panel - user manual 24 switches a variety of switches are available for protecting doors and windows. The line-up includes surface and flush mount reed switches, emergency buttons, roller door reed switches and the unique e-techensor™ vibration sensor for highly effective perim...

  • Page 25

    E-tech et8 v4 control panel - user manual 25 wireless products radio accessories ask your installer about the range of e-tech radio devices for the optional extra convenience of wireless remote control and wireless detection. Operating your e-tech security system can be as convenient as opening your...

  • Page 26

    E-tech et8 v4 control panel - user manual 26 symptom possible cause remedy zone light on or long beeps when arming one or more zone detection devices (e.G., pir, reed switch) may be unsealed close door or window, find the cause of movement 10 beeps from keypad mains light flashing battery light flas...

  • Page 27

    E-tech et8 v4 control panel - user manual 27 date purchased: installation record date installed: installation company: telephone: monitoring company: telephone: zones device type pir, reed switch, etc entrance, bedroom1, etc description p41e entry dela y 1 zone assignment p43e entry dela y 2 p42e ha...

  • Page 28

    E-tech et8 v4 control panel - user manual 28 operation summary arm disarm monitor mode panic keypad duress excluding zones alarm memory or... Or... Or... Or... Or... Press repeatedly to display the last 30 events or... Both keys together (keypad panic shortcut must be on, p62e 4e) press and hold for...