Earlex Combivac User Manual - page 6
––
6
TROUBLE SHOOTING
IF A PROBLEM OCCURS ALWAYS SWITCH THE UNIT OFF IMMEDIATELY
Motor does not operate.
Check unit is plugged in and switched on.
Check fuse in plug - replace only with a fuse of the same rating -
13 amps and marked BS1362.
If using extension lead check the fuse in this lead.
Motor operates but cleaner fails Check if the cleaner needs emptying.
to pick up.
Check and clear any blockages within the system.
Check that the combined filter is not damaged.
Motor makes high pitched noise. Check if cleaner needs emptying and the float valve has operated.
Dust/grit blowing from outlet.
Check filter is correctly fitted, if heavy duty filter is used check that it is
fully pushed into position.
Maintenance
After wet pick up empty, rinse and dry the recovery tank, hose and accessories. If vacuuming/collecting
sticky spills, clean the tank and accessories with warm, soapy water.
Periodically replace the Dust Collection Bag.
Do not oil the motor. It is lubricated for life.
There are no serviceable parts inside the cleaner apart from the filters.
AFTER SALES SERVICE
A range of accessories together with all spare parts are available from our service department who will
furnish details for you.
IF YOU REQUIRE FURTHER ASSISTANCE THEN PLEASE CONTACT OUR HELPLINE ON
Tel: 01483 454666 Fax: 01483 454548 email:enquiries@earlex.co.uk
Opening Hours: Monday-Friday 08.30-17.00 (excluding Bank Holidays)
GUARANTEE
This product is guaranteed for a period of two (2) years against faulty materials and workmanship. The
guarantee specifically excludes the use for hire or rental purposes.
Whilst every possible care is taken by Earlex to ensure that our products leave the factory in good working
order, Earlex cannot under any circumstances accept liability for problems or damage caused by use of
such products not in adherence to the instructions enclosed. Any unit that has been modified in any way or
used on incorrect voltage will not be covered by guarantee. Consumables such as filters are not covered
by guarantee.
This guarantee does not affect your statutory rights. In the event of a fault occurring please contact our
helpline before returning the unit to our Service Department at the address below together with a copy of
your purchase receipt. All repairs will be dealt with speedily.
EC Declaration of Conformity
We declare that units: WD1000, WD1100 and WD1400 conforms to: 2006/95/EC, EN60335-2-2 &
2004/108/EC, EN55014-1, EN55014-2, EN61000-3-2, EN61000-3-3, EMF EN62233
Tim Hopper Technical Director
Copyright Reserved © 2011
WD0327-06-11.qxd:WD0046-03/05.qxd 9/6/11 09:19 Page 6