Earlex Combivac User Manual - page 7
ACCESSORIES AND SPARE PARTS
A range of spare parts are available for the CombiVac
TM
. To order please contact our helpline on
01483 454666. Opening Hours: Monday-Friday 08.30-17.00 (excluding Bank Holidays).
WDACC2 - Deluxe Floor Head with hard floor, brush and squeegee attachments. Wider head for greater
coverage, suitable for carpets and faster pickup of debris and spills.
WDACC10 - Pack of three spare foam filters.
WDACC11 - Pack of three spare paper filters.
WDACC12 - Power Tool Adaptor.
WDACC13 - Combined Wet & Dry Filter no need for foam filter or paper filter and no need to change
between filters for dry or wet pickup.
WDACC14 - Wide Bore Tool Kit for larger debris such as rubble and leaves.
WDACC15 - Mini Cleaning Set - ideal for cleaning/blowing computers, video recorders, air vents in cars.
WDACC16 - Sink Deblocker - clears blockages from sinks, baths and showers.
WDACC18 - Combispray - Multipurpose spray gun
WDACC19 - Dust Collection bags - Dust bags suitable for collecting fine dust.
WDACC20 - Cellulose Cartridge Filter - Wet ʻn Dry vacuum filter, not recommended for prolonged wet use.
MAINS CONNECTION
This unit is a Class II appliance which means it is double insulated for your protection, no earthing wire is
necessary.
If the supply cord is damaged, the whole appliance must be referred to a qualified Earlex engineer or
appointed agent.
Your unit has been supplied with a mains lead with a fitted plug. This is identified by the fuse holder in the
base of the plug. Please read the following safety instructions before use.
1. If the fitted plug is cut off from the mains lead then the plug must be disposed of safely.
NEVER under any circumstances insert such a plug into a 13 amp socket.
2. NEVER under any circumstances use the appliance or mains lead without the fuse cover fitted.
This is the little cover fixed into the base of the plug to hold the fuse in place.
3. If you lose the fuse cover do not operate until a cover is fitted or ring our helpline.
4. A replacement fuse must be rated at 13 amp. These must be manufactured and approved to BS 1362.
5. IF IN ANY DOUBT CONTACT A QUALIFIED ELECTRICIAN.
If you need to fit a plug to the mains lead, this should be fitted in accordance with the wiring
instructions below, and will need to be used with a BS1362 approved 13A fuse. If in doubt consult a
qualified electrician.
If you are using an extension lead it must be rated at a minimum of 6 amps and fully unwound. Do not
operate with a lead rated at less than 6 amps as this will cause premature failure of the motor which
is not covered by the guarantee.
As the colours of the wires in the mains lead of the application may not
correspond with the coloured markings identifying the terminals in your plug,
proceed as follows:
The wire which is coloured blue or black must be connected to the terminal
which is marked with the letter N.
The wire which is coloured brown or red must be connected to the terminal
which is marked with the letter L.
7