EarthCore ISF-SBVT24VE(N,P) Installation & Owner's Manual - Systèmes De Brûleur:

Manual is about: STADIUM BURNER VENTED SYSTEMS

Summary of ISF-SBVT24VE(N,P)

  • Page 1

    1 rev 0 - 1706060745 l-a2-420 earthcore industries, llc. • 6899 phillips industrial blvd • jacksonville, fl 32256 the isoflames burner system is to be installed only in a solid-fuel burning fi replace with a working fl ue and constructed of noncombustible material. The installation, including provis...

  • Page 2: Systèmes De Brûleur:

    2 rev 0 - 1706060745 l-a2-420 earthcore industries, llc. • 6899 phillips industrial blvd • jacksonville, fl 32256 le isoflames système de brûleur doit être installée seulement dans une cheminée brûlante de combustible solide avec une conduite de cheminée fonctionnante et être construit avec du matér...

  • Page 3

    3 rev 0 - 1706060745 l-a2-420 table of contents getting started important pre-installation and fireplace safety information ........................................... 5 fireplace operating safety information ....................................................................................... 7 s...

  • Page 4

    4 l'information de sÛretÉ importante de prÉinstallation et de cheminÉe a. Faites attention: sinon installé, entretenu, et utilisé correctement par ces instructions, ce produit peut causer le dommage corporel, les dégats matériels, ou les pertes humaines sérieux. B. Avertissement: avant l'installatio...

  • Page 5

    5 important pre-installation and fireplace safety information a. Be careful: if not installed, serviced, and used correctly per these instructions, this product can cause serious personal injury, property damage, or loss of life. B. Warning: before installing in a solid-fuel-burning fi replace, the ...

  • Page 6

    6 informations sur la sÉcuritÉ d'exploitation de cheminÉe a. Adultes doivent être présents lors de cet appareil au gaz est en marche. Cette unité ne doit pas être laissé sans surveillance ou brûlure lorsque tout quelqu'un dort. B. Gardez le domaine du clair réglé de notation de gaz et libérez des ma...

  • Page 7

    7 fireplace operating safety information a. Adults shall be present when this gas appliance is operating. This unit shall not be left burning when unattended or while anyone is sleeping. B. Keep the area of the gas burner system clear and free from combustible materials, gasoline, and other fl ammab...

  • Page 8

    8 isoflames gas burner systems must be installed only in a wood burning fi replace with the minimum fi rebox dimensions and venting requirements met (see table on this page). This appliance is designed to burn with yellow fl ames; adequate ventilation is absolutely necessary. Specifications table 1 ...

  • Page 9

    9 specifications (cont.) wiring diagram valve motor wire harness battery pack ignition module fig. 9-1 insulated copper black s i main wire harness white green orange red black main g a s inlet step motor main fl ame (main gas out) (pilot gas out) main fl ame step output copper black (gnd) pilot pil...

  • Page 10

    10 damper clamp set screw open closed damper clamp instructions fig. 10-1 damper clamp detail fig. 10-2 damper open / closed the damper clamp with hex bolt ( fig. 10-1 ) is provided as a means to prevent full closure of the damper blade. The clamp is easily attached to most damper blades with pliers...

  • Page 11

    11 12 burner parts list note: photos not to scale replacement parts can be ordered from your local isoflames dealer. Bottom view 15 9 6 2 3 pilot 1 7 13 electrode 10 4 thermocouple 11 5 remote transmitter and switch box batteries included with burner system. 24/30 burner model shown 8 flash tube the...

  • Page 12

    12 refer to the parts list when following these instructions. 24/30 burner model shown here. Burner installation 1. Make sure the fireplace gas supply is turned off. 2. Locate the gas-supply stub inside the fi replace and remove the cap, if attached (reference fig. 12-1). Caution: when removing the ...

  • Page 13

    13 important for all valves, the air must be purged from the gas line before the pilot will light and burn properly. The time needed to purge will depend on the length of the gas line to the unit and the amount of time since the unit or gas line was last used. It may take several minutes before all ...

  • Page 14

    14 installation (cont.) caution: burn hazard! Logs will remain hot for some time after use. If you need to reposition any log to maintain the proper layout, use heat-resistant gloves or allow logs adequate time to cool before handling. Log set placement • follow the instructions included with the lo...

  • Page 15

    15 installing/replacing batteries caution: ensure the unit is connected to the gas line and has been tested for leaks before you insert batteries. Caution: turn off the remote and/or burner and allow the unit to completely cool prior to any battery replacements. Important: prior to inserting batteri...

  • Page 16

    16 notes page please use this page to record any information that you may want to have at hand..

  • Page 17

    17 i o lighting instructions for your safety, read before lighting warning: if you do not follow these instructions exactly, a fi re or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition device that automatically lights the p...

  • Page 18

    18 i o pour votre sÉcuritÉ lisez avant d'allumer avertissement: si vous ne suivez pas ces instructions à la lettre, un incendie ou une explosion entraînant des dommages matériels, des blessures ou des pertes de vie. A. Cet appareil est équipé d'un dispositif d'allumage qui allume automatiquement la ...

  • Page 19

    19 i o lighting instructions (cont.) manual lighting caution: do not attempt to light the pilot by hand. 1. Locate the off/remote slide actuator on the left rear of the burner. Slide the actuator to the left / off position. See fig. 19-1. 2. Locate the on/off switch at the front of the switch box. P...

  • Page 20

    20 i o instructions d'allumage (cont.) allumage manuel attention: ne pas essayer d'allumer la veilleuse manuellement. 1. Localisez actionneur coulissant off/remote sur le côté gauche du brûleur. Glisser le servomoteur sur la position gauche / off . Voir fig. 20-1. 2. Repérez l'interrupteur on/off su...

  • Page 21

    21 remote operating instructions orientation prior to remote transmitter use, light the appliance per the remote lighting section. The remote transmitter will only operate the unit when it is in the remote mode. Familiarize yourself with the transmitter buttons, as illustrated in fig. 21-1. Identify...

  • Page 22

    22 mode d'emploi À distance orientation avant la première utilisation télécommande, allumez l'appareil pour la section d'éclairage à distance. La télécommande ne fonctionne que l'appareil quand il est en mode distant. Familiarisez-vous avec les touches de l'émetteur, comme illustré dans la fig. 22-1...

  • Page 23

    23 note: servicing may be necessary to ensure proper pilot operation and proper burn characteristics. Always shut off the gas to the appliance while performing service work. Allow the appliance to cool before servicing. Installation, service, and repair must be done by an nfi certifi ed or other qua...

  • Page 24

    24 cleaning and servicing (cont.) fig. 24-2 flame appearance observe the fl ames. The top and middle burner fl ames should be blue at the base and a combination of blue/yellow at the body and at the tips. The top fl ames should be approximately 3-5" above the logs, with the center fl ame being the t...

  • Page 25

    25 troubleshooting possible cause solutions burner shutting down during operation a. Insuffi cient or excessive gas pressure a1. Check gas pressure (read d.- f. Of important pre-installation and fireplace safety information section, & check with local gas company). A2. Other gas appliances may be on...

  • Page 26

    26 troubleshooting (cont.) possible cause solutions sooting a. On logs, in fi rebox, or room a. Check gas pressure (see section 1, a1 of this table). B. Drafts in room b. Eliminate drafts by closing heating and air conditioning vents, returns, and outside air vents. Fans blowing directly into fi rep...

  • Page 27

    27 customer service earthcore industries, llc is committed to customer service and exceeding customer expectations. We are available monday - friday 8:30 am to 4:30 pm est toll free at 800 642-2920 to provide technical assistance and answer any questions you may have. Warranty the warranty mentioned...

  • Page 28

    28 warranty card please cut along dashed lines and send to: earthcore industries, llc 6899 phillips industrial blvd. Jacksonville, fl 32256 attn: technical department warranty card date of purchase: _________________________________________________________________ name: _____________________________...