EarthQuake XJ-1000FR User manual

Manual is about: 2 CHANNELS / 1000 WATTS / HIGH EFFICIENCY / CLASS “J” / FULL RANGE AMPLIFIER

Summary of XJ-1000FR

  • Page 1

    Xj-1000fr user manual p r o pc & mac compatible 2 channels / 1000 watts / high efficiency / class “j” / full range amplifier earthquake sound corporation. Www.Earthquakesound.Com 2727 mccone avenue, hayward ca, 94545 phone: (510) 732-1000 / fax: (510) 732-1095.

  • Page 2: P R O

    A thank you note. © 2012 earthquake sound corporation. All rights reserved. This document should not be construed as a commitment on the part of earthquake sound corporation. The information is subject to change without notice. Earthquake sound corporation assumes no responsibility for errors that m...

  • Page 3: P R O

    Warranty information page 3 p r o www.Earthquakesound.Com xj-1000 fr product registration this xj-1000fr power amp can be registered by returning the product registration card attached to this manual. Please also retain the sales receipt which represents proof of purchase and helps expedite warranty...

  • Page 4: P R O

    From our hands to your ears... Thank you. Joseph j. Sahyoun; your brother in sound president & chief engineer page 4 p r o www.Earthquakesound.Com a word from the president first of all, thank you for purchasing this xj-1000fr power real innovations and real technology invented right here in amplifi...

  • Page 5: P R O

    Page 5 p r o www.Earthquakesound.Com safety first xj-1000 fr important safety instructions 1) read these instructions in their entirety. 11) only use attachments & accessories specified by the manufacturer. 2) store this manual and packaging in a safe place. 12) use only with a cart, stand or table ...

  • Page 6: P R O

    Front panel rear panel 1 2 6 7 14 13 13 12 11 10 8 9 9 15 page 6 p r o www.Earthquakesound.Com front / rear panels xj-1000 fr on/off control function operation keys mute control preset eq mode select directly back to the ir control: nec protocol customer code: 00hffh main screen store hot key recall...

  • Page 7: P R O

    Output level meter lock enable bridge on filter on subsonic on externa l trigger enable unmuted muted eq mode xj-1000fr boot screen xj-1000fr main screen volume control explanation of symbols on screen page 7 p r o www.Earthquakesound.Com lcd display functions xj-1000 fr xj-1000fr press remote contr...

  • Page 8: P R O

    When the selection is complete/set, the option in the main screen will display the corresponding icon. Lpf (low pass) & hpf (high pass) filters control subsonic = off filter = off filter = low pass (lpf) filter = high pass (hpf) subsonic filter control (50hz~4000hz) (50hz~4000hz) page 8 p r o www.Ea...

  • Page 9: P R O

    User eq only available when in user mode external trigger equalizer modes lock setting the “ external trigger” setting is used to allow an external 12 v trigger source to turn the amplifier on and off with a 12 v trigger from another device. Six equalizer modes to choose from: no-equalization (flat)...

  • Page 10: P R O

    Press right key or encode turn right to enter function. There are 3 independent memories that can be used to save all the dsp settings as a single configuration. Once you have finished programing all the features, select a memory location (1,2, or 3) and press enter key to save. There are 4 memory l...

  • Page 11: P R O

    3- now you must decide the folder name from where you can access the program start. 4- once this is done an information screen with the defined installation options will appear and once confirmed the installation will automatically start. 5- now the drivers’ installation screen will appear. Once the...

  • Page 12: P R O

    2 3 4 9 8 7 1 5 6 software control panel 1. Load specified file setting. 2. Click file/load. 3. Select a configuration file(.Dat) for loading. 4. Load configuration to control panel for preview. Load 1. Write specified file setting to amplifier. 2. Configuration data has to be loaded with file/load ...

  • Page 13: P R O

    6- external trigger control external trigger switch external trigger status 2- volume control mute sound volume control ( - 80db~0db) green = on red = off 7- memory store/recall control 3- subsonic control subsonic on/off frequency setting (16-30 hz) 5- phase control (0 °/45 °/90 °/135 °/180 °/225 °...

  • Page 14: P R O

    8- user equalizer gain control page 14 p r o www.Earthquakesound.Com how to program user eq xj-1000 fr specifications xj-1000 fr power output frequency response total harmonic distortion slew rate signal to noise ratio load impedance damping factor input connections output connections power requirem...

  • Page 15: P R O

    Page 15 p r o www.Earthquakesound.Com xj-1000 fr amplifier “on” no sound a) completely shut your system down including your amplifier via the circuit breaker. B) now turn on the amplifier only. Check to see if the front main power switch is on. C) check the input selector switch and make sure that i...

  • Page 16: P R O

    Earthquake sound reserves the right to amend details of the specifications without notice. © copyright earthquake sound corporation earthquake sound corporation 2727 mccone avenue, hayward ca, 94545 phone: (510) 732-1000 u.S. Toll free: (800) 576-7944 fax: (510) 732-1095 p r o.