Easy-Kleen MAG4000 User Manual - page 5
5
C) INSTALLATION INSTRUCTIONS
These water heaters are intended for outdoor use only due to their need for
adequate ventilation for the gasoline powered engines.
D) BASIC CONTROLS
The burners on these pressure washer's require a source of electrical power to create
ignition. Optionally each model can generate 12V DC for this purpose or on the
base model 120V electrical connection.
WARNING:
This controller must be provided with suitable overload and
overcurrent protection in accordance with the Canadian Electrical
Code part 1.
Avertissement:
Ce contrôleur doit être muni d’une protection contre la
surcharge et la sur intensité, conformément au Code
canadien de l’électircité, Première partie.
UNIT TO BE CONNECTED TO A (GFCI) OR TWIST
LOCK PLUG OR PERMANENT CONNECTION
A high pressure switch prevents burner operation without water flow. The
thermostat's "On-Off" function is provided for manual control.
E) OPERATING INSTRUCTIONS
To Operate Burner
Be sure water is flowing through water heater coil before turning on burner switch.
Start the gasoline engine and wait until a steady stream of water is flowing from
the spray gun. Turn thermostat to desired temperature. Burner will ignite and
remain in operation as long as there is sufficient water flow to satisfy the pressure
switch and temperature control. To shut off burner, turn temperature switch to
"Off".
Condensation From Coil
When cold water is being pumped through the heater coil and the burner is firing,
condensation may form at times on the coil and drip down into the burner
compartment. This can be particularly noticeable on cold, humid days giving the
false appearance of a leaking coil.