GENERAL INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
FOR STRAIGHT “S” SERIES HEATER
“S” series straight heaters consist of burner, 2-10 ft. (.6 to 3 meters) radiant tubes, 2-10 ft. (.6 to
3 meters) reflectors and four plated hangers. For access to controls, remove screw in center of
doors and swing open.
The hangers included with the straight model “EZ DUZZIT” heater have two available
suspension rings. If the reflector is to be flat the hangers should be suspended from the top ring.
If the reflectors are to be angled, the hangers should be suspended from the side ring. Using the
chain provided, suspend the four hangers from the ceiling ensuring that the radiant tube will be
parallel to the floor, with strict adherence to the clearances to combustibles as listed in this
manual and the rating plate on the burner. Suspend the hangers from either the top or side ring
on the hanger as desired.
Once the hangers are suspended the 3-1/2” dia. radiant tubes can be placed in the hangers
ensuring that the sight glass is pointing down. Ensure that the enlarged end of the 3-1/2” primary
tube, with the setscrew is at the desired location for the burner. Fit the 3-1/2” primary tube into
the enlarged end of the 3-1/2” dia. secondary tube. Install the screw provided through the
predrilled hole in the secondary tube and into the primary tube in order to secure the two tubes
together. With the tubes in place, the reflectors can now be laid into the hangers.
Remove the protective plastic cap from the nozzle of the burner and place the nozzle end of the
burner into the enlarged end of the radiant tube. Tighten the setscrew so as to secure the burner
into place.
For installation instructions in the United States this appliance must not be installed less than 8
ft. (2.4 meters) above the floor. In Canada it cannot be installed less than 7 ft. (2.1 meters) from
the floor. It must be installed with strict adherence to clearances to combustibles.
Install thermostat approximately 5’6” (1.6 meters) above floor and not located in the direct ray of
the heater. Remove the jumper wire on the burner (marked 24 V thermostat) and using 24 Volt
wiring connect from terminals on the burner to the thermostat.
Reflector
Hangers Qty. 4
9 ft. 6 in.
Thank you for purchasing the “EZ DUZZIT” residential garage heater. You have purchased either an “S” straight
model or “U” U-shaped model. Follow the appropriate installation instructions for the model you are installing.
“EZ DUZZIT” residential garage heaters are self-contained heating
appliances that require gas supply & 120 V electrical supply. Qualified
individuals must do all gas and electrical connections with strict adherence to
all applicable codes. The heaters must be vented to the outside (through the
wall or roof). Ducting of combustion air from outside is optional, but may be
necessary in certain applications (see combustion air venting).