The PA12 aerator features a 1/8 horse power
continuous duty air compressor, 50' of tubing
and a pond diffuser.
Once the air diffuser is assembled and the tub-
ing is attached, you are ready to install the dif-
fuser. Always unroll the tubing completely
before installing the diffuser. The diffuser can be
lowered into your pond with a rope. Often a
float, such as a duck decoy or a milk jug, will be used so retrieval of the diffuser is possi-
ble.
Assembly:
1. Unpack all the parts. Compare parts with packing list below to ensure all parts were
received. If a shortage occurs, please notify us immediately.
2. Screw the two airstones into the PVC manifold. Do not overtighten! Hand tighten only!
3. Slide one end of the tubing onto the barbed adapter coming out of the PVC manifold.
Clamp this connection using the clamp provided.
4. Position the PVC manifold and airstones onto the white plastic underlay. Use the plastic
straps provided to attach the manifold to the underlay.
5. Attach the other end of the tubing to the compressor and tighten.
After one or two years of operation, you will possibly notice a sudden drop in air bubbles.
This is a sure sign that the diaphram has cracked and needs replacing. Repair kit DC12RK
has all the items necessary to rebuild your compressor.
Be sure to clean the inlet air filter on your compressor regularly. Wash dirty air filters in
soapy water. Replacement filters are available.
PA12 Packing List:
Description.
Qty.
Packed
Air Compressor w/filter
1
PVC Manifold w/Check Valve
1
Air Diffusers
2
Tie Straps
3
Tubing Clamps
2
50' Roll Tubing
1
____' Additional Tubing
12" x 21" Underlay
1
Packed By:
Date:
# of Boxes: