EAT C-Major Instructions For Use Manual

Other manuals for C-Major: Operating Manual

Summary of C-Major

  • Page 1

    European audio team instructions for use e.A.T. C-major.

  • Page 2

    2 dear music lover, welcome! Congratulations on your purchase of our e.A.T. C-major turntable. Your e.A.T. C-major was handcrafted by our skilled technicians here at the european audio team. It has been rigorously tested and is ready and waiting for your enjoyment. Please take the time to read this ...

  • Page 3

    3 contents product illustrations and key 4-5 setup 1. Transport screws 6 2. Sub-platter and drive belt installation 6-7 3. Platter installation 7 4. Tonearm assembly 8 a) cartridge assembly 9 b) counterweight assembly 9 c) vertical tracking force setting (vtf) 10 d) tonearm output connection 11 e) v...

  • Page 4

    4.

  • Page 5

    5 key: controls, features and connections 1. On/off switch 2. Platter with bonded vinyl mat 3. Record clamp 4. Tonearm counterweight 5. Tonearm lift lever 6. Tonearm rest 7. Headshell with finger lift 8. Anti-skating mechanism 9. Floating sub-chassis 10. Rca output with earth connection 11. Power su...

  • Page 6: Setup

    6 setup 1. Transport screws remove the three transport screws (15) from the carbon part of the chassis before installing the sub-platter (14), the drive belt (13) and the platter (2). The transport screwsare used to ensure safe shipping and transport, and should be reinstalled prior to any future sh...

  • Page 7

    7 3. Platter installation install the platter (2) on the sub-platter (14)..

  • Page 8

    8 4. Tonearm assembly the tonearm includes a combination of cardan and uni pivot bearings, immersed in special damping fluid. See the next steps to set up your tonearm..

  • Page 9

    9 a) cartridge installation install the cartridge into the aluminium headshell, using the appropriate hardware included with your cartridge. Connect the cartridge as indicated below: • white left channel l+ • red right channel r+ • green right channel r- • blue left channel l- for correct cartridge ...

  • Page 10

    10 c) vertical tracking force setting (vtf) before setting the vertical tracking force, confirm the exact weight of your cartridge. Depending on your cartridge weight, determine whether to use the counterweight with or without the additional insert, in accordance with the specifications above. Pushi...

  • Page 11

    11 d) tonearm output connection connect the tonearm cable provided with the accessories to the rca tonearm output that is located at the rear of the turntable, behind the tonearm. Connect the grounding cable on the earth connection screw. E) vertical tracking angle setting (vta) to set the vertical ...

  • Page 12

    12 f) azimuth setting the cartridge needle must be perpendicular to the record in order to trace the groove wall modulations correctly. The azimuth (angle) is precisely set by the factory. In the event that you need to modify this setting, however, follow the instructions below. Step 1: unscrew the ...

  • Page 13

    13 xamples of incorrect azimuth setup: too much left angle: too much right angle: the correct position is 100% perpendicular to the record..

  • Page 14

    14 g) anti-skating assembly and adjustment the anti-skating mechanism is shipped partially disassembled to avoid damage during transport. For correct installation, please follow the steps below. Step 1: prepare all parts supplied from the accessories bag: • anti-skating sliding mechanism with anti-s...

  • Page 15

    15 step 3: the anti-skating sliding mechanism is supplied with a pre-mounted anti-skating weight and anti- skating thread. Put the eye of the anti-skating thread around the hole for the hook screw and screw the hook screw into the tonearm through the eye of the anti-skating thread as shown in the il...

  • Page 16

    16 step 5: anti-skating force adjustment: adjust the anti-skating force by positioning the weight on the appropriate groove of the anti- skating sliding mechanism. Anti-skating downforce should be adjusted in correspondence with the tonearm downforce as follows: tonearm downforce: anti-skating groov...

  • Page 17

    17 three precision adjustable damped feet are mounted under the turntable for leveling the turntable. Once the turntable is in final position, put the supplied spirit level on the carbon fiber sub-chassis, and then level the turntable by screwing or unscrewing the feet as needed. It is advisable to ...

  • Page 18

    18 7. Technical specifications e.A.T. C-sharp model c-major nominal speed 33/45 rpm, manual speed change speed variance 33rpm: ± wow and flutter 33rpm: ± signal to noise s/n ratio (mechanical noise): - 40 db s/n ration (electrical noise): -68 db downforce range 0 - 30 mn 0 - 3.0 grams supplied count...

  • Page 19

    19 troubleshooting the platter doesn’t turn although the unit is switched on: • the unit is not connected to the mains power supply (the building’s electrical system). • no mains power is being delivered at the socket. • the drive belt is not fitted properly or has slipped off. No signal through one...

  • Page 20