Eaton 1400 Series Installation & maintenance instructions manual

Manual is about: Flame Proof Camera Housings & Pan Tilt Units

Summary of 1400 Series

  • Page 1

    Imi+70-xf-xc-xp-xt issue 7 2400 & 1400 series (xp, xt, xc & xf) flame proof camera housings & pan tilt units installation & maintenance instructions this manual should be read before attempting to connect or operate the equipment this equipment shall be installed in accordance with the latest local/...

  • Page 2

    Eaton installation & maintenance instructions imi+70-xf-xc-xp-xt issue 7 © 2016, eaton page 2 of 21 amendment record issue date details of amendment 1.0 first issue 2.0 09/03/2016 inclusion of annexes 3.0 05/04/2016 inclusion of ex ia removal of ratings page 5 additions to annexe e 4.0 06/04/2016 ch...

  • Page 3

    Eaton installation & maintenance instructions imi+70-xf-xc-xp-xt issue 7 © 2016, eaton page 3 of 21 section page amendment record 3 1.0 general 4 1.1 important safeguards and warnings 4 2.0 description 5 2.1 versions 6 2.2 supplied equipment 6 2.3 associated equipment 6 2.4 recommended tools 6 2.5 r...

  • Page 4

    Eaton installation & maintenance instructions imi+70-xf-xc-xp-xt issue 7 © 2016, eaton page 4 of 21 1.0 general 1.1 important safeguards and warnings this symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit. Prior to installation ...

  • Page 5

    Eaton installation & maintenance instructions imi+70-xf-xc-xp-xt issue 7 © 2016, eaton page 5 of 21 2.0 description the 2400 & 1400 series camera assemblies have been developed to meet the rigorous requirements of flame proof and dust-ignition-proof electrical equipment for installation and use in h...

  • Page 6

    Eaton installation & maintenance instructions imi+70-xf-xc-xp-xt issue 7 © 2016, eaton page 6 of 21 2.0 description (continued) the project requirements and unit certification label must be checked by the installer before installation, to confirm that the product supplied is suitable for the intende...

  • Page 7

    Eaton installation & maintenance instructions imi+70-xf-xc-xp-xt issue 7 © 2016, eaton page 7 of 21 3.0 installation in order to ensure proper wiring and system operation of all components, it is recommended that all units and all associated control equipment be tested at your factory before field i...

  • Page 8

    Eaton installation & maintenance instructions imi+70-xf-xc-xp-xt issue 7 © 2016, eaton page 8 of 21 fig.1 xp26vw example xp series unit showing base mount fixing points fig.2 bpw6800 wall bracket.

  • Page 9

    Eaton installation & maintenance instructions imi+70-xf-xc-xp-xt issue 7 © 2016, eaton page 9 of 21 fig.3 xc40vw example xc series unit showing shaft mount fixing points fig.5 bfp0600/900/1200 column spacer fig.4 bfw5000 wall bracket.

  • Page 10

    Eaton installation & maintenance instructions imi+70-xf-xc-xp-xt issue 7 © 2016, eaton page 10 of 21 fig.6 xf60vn example xf series unit showing mount plate fixing points fig.7 bfp00sw swivel joint & pole top adaptor fig.8 bfw32sw swivel joint & pole top adaptor 3.2.3 mounting the xf series the xf s...

  • Page 11

    Eaton installation & maintenance instructions imi+70-xf-xc-xp-xt issue 7 © 2016, eaton page 11 of 21 fig.9 mid and long housing sunshield installation fig.10 short housing sunshield installation 3.3 accessory installation 3.3.1 sunshield installation sunshields are supplied uninstalled to prevent da...

  • Page 12

    Eaton installation & maintenance instructions imi+70-xf-xc-xp-xt issue 7 © 2016, eaton page 12 of 21 fig.11 260mm housing washer nozzle fig.12 400mm housing washer nozzle fig.13 non-continuous rotation p&ts and fixed housings washer nozzle 3.3.2 washer nozzle installation a continuous rotation p&t s...

  • Page 13

    Eaton installation & maintenance instructions imi+70-xf-xc-xp-xt issue 7 © 2016, eaton page 13 of 21 3.4 electrical installation electrical installation and servicing should only be carried out by qualified service personnel and in accordance with all local/national codes of practice and standards e...

  • Page 14

    Eaton installation & maintenance instructions imi+70-xf-xc-xp-xt issue 7 © 2016, eaton page 14 of 21 fig.14 gaining access to the xp and xt base junction box 230vac n switch l 24vac pump supply data a + data b - n 24vac pump supply earth 230vac l video screen video signal 110vac n switch l 24vac pum...

  • Page 15

    Eaton installation & maintenance instructions imi+70-xf-xc-xp-xt issue 7 © 2016, eaton page 15 of 21 fig.15 removing the wiper arm fig.16 removing the front window flange fig.17 removing the rear flange 3.4.3 electrical installation xf & xc series units 1. Cable entry type to the housing is via 1 x ...

  • Page 16

    Eaton installation & maintenance instructions imi+70-xf-xc-xp-xt issue 7 © 2016, eaton page 16 of 21 3.3.4 xc & xf common connection examples always refer to project specific drawings and information 230vac n data a + data b - 230vac l 230vac model with pump output nc earth switch l 24vac pump suppl...

  • Page 17

    Eaton installation & maintenance instructions imi+70-xf-xc-xp-xt issue 7 © 2016, eaton page 17 of 21 4.0 maintenance recommended inspection interval: 6 months. Inspect the unit every six months to ensure trouble free operation and extend product life. Due to the rugged construction of the unit, litt...

  • Page 18

    Eaton installation & maintenance instructions imi+70-xf-xc-xp-xt issue 7 © 2016, eaton page 18 of 21 5.0 labelling the labels are printed on self adhesive metalized vinyl and affixed product. The contents of the label will be in english. The label shows: a - name of manufacturer , b - model/type and...

  • Page 19

    Eaton installation & maintenance instructions imi+70-xf-xc-xp-xt issue 7 © 2016, eaton page 19 of 21 6.0 specifications, technical data & special conditions for safe use. Coding iecex & atex ii 2 g exdb iic t6-3*gb -##°c ≤ ta ≤ +##°c ii 2 d ex tb iiic t135°c db ip66/67 illuminator ii 2 g exdb op is ...

  • Page 20

    Eaton installation & maintenance instructions imi+70-xf-xc-xp-xt issue 7 © 2016, eaton page 20 of 21 a. Ex annexe special conditions of certification (a) specific conditions for safe use. 1. No modifications must be made to the flamepaths of the unit without consultation of the drawings listed on th...

  • Page 21

    Eaton installation & maintenance instructions imi+70-xf-xc-xp-xt issue 7 a. Ex annexe continued (b) conditions of manufacture, routine tests , a routine overpressure test in accordance with iec 60079-1:2014 clause 16.1 shall be carried out on all enclosures, including all cemented window assemblies,...