6.0
Specifications, Technical data & Special conditions for safe use.
Coding IECEx & ATEX
II 2 G Exdb IIC T6-3*Gb -##°C ≤ Ta ≤ +##°C
II 2 D Ex tb IIIC T135°C Db IP66/67
Illuminator
II 2 G Exdb op is IIC T4/3 Gb -##°C ≤ Ta ≤ +##°C
II 2 D Ex tb op is IIIC T135°C Db IP66/67
Fibre Optic
II 2 G Exdb op pr IIC T6…3*Gb -##°C ≤ Ta ≤ +##°C
II 2 D Ex tb op pr IIIC T135°C Db IP66/67
Wireless
II 2 G Ex db ????[Ex ia Ga] IIC T6…T5 Gb -##°C ≤ Ta ≤ +##°C
II 2 D Ex tb ????[Ex ia Ga] IIIC T135°C Db IP66/67
???? = Optional op pr/op is coding
Note: T class and ambient temperature, is dependent on the assembly configuration and
maximum internal power dissipation.
*=T class, Gas Group
## = Ambient Temperature range
Construction:
Stainless Steel AISI 316L
Ingress Protection rating:
IP 66/7
Max Weight:
Integrated Pan Tilt with housing :
40-62Kg depending on model
Standalone housing:
12-22Kg depending on model
Mounting:
Integrated Pan Tilt with housing :
4-x M10 fixings on 182mm pcd
Standalone housing:
Depending on mounting brackets
Supply voltage:
24VAC, 50/60Hz or
100 to 230VAC with integral transformer
Power consumption:
Max 120 Watts depending on model
7.0
Special Conditions for Safe Use.
1. No modifications must be made to the flamepaths of the unit without consultation of the
drawings listed on the schedule.
2. Temperatures could exceed 70°C at the cable gland or 80°C at the branching point,
suitably rated cable must be selected.
3. Use only hex socket head fasteners with property class of A4-70 for securing end covers &
shafts to housings.
4. No electromagnetic or ultrasonic energy radiating equipment shall be fitted within the
enclosures other than armoured/protected fibre optic cables (op pr) or the IR illuminator as
specified in the documents.
5. When fitted the optical fibre output from the camera housing must always be terminated
within a suitably certified enclosure or safe area.
6. Only armoured cable or conduit is to be utilized when fitted with a fibre optic output in
order to protect the fibre optic cable.
7. Precautions must be taken to avoid dust from forming layers on the equipment.