Eaton 5PX 1500i RT2U Installation And User Manual - 5. Maintenance

Summary of 5PX 1500i RT2U

  • Page 1

    English 5px 1500i rt2u 5px 2000i rt2u 5px 2200i rt2u 5px 3000i rt2u 5px 3000i rt3u 5px ebm 48v rt2u 5px ebm 72v rt2u 5px ebm 72v rt3u installation and user manual copyright © 2010 eaton all rights reserved. Service and support: call your local service representative 614-07977-00_en.

  • Page 2

    Page 2 614-07977-00_en certification standards special symbols the following are examples of symbols used on the ups or accessories to alert you to important information: risk of electric shock - observe the warning associated with the risk of electric shock symbol. Important instructions that must ...

  • Page 3: Contents

    Page 3 614-07977-00_en english contents 1. Introduction ....................................................................................... 4 1.1 environmental protection.................................................................................................4 2. Presentation ..............

  • Page 4: 1. Introduction

    Page 4 614-07977-00_en 1. Introduction thank you for selecting an eaton product to protect your electrical equipment. The 5px range has been designed with the utmost care. We recommend that you take the time to read this manual to take full advantage of the many features of your ups (uninterruptible...

  • Page 5: 2. Presentation

    Page 5 614-07977-00_en english 2. Presentation 2.1 standard positions tower position d w h d w h rack position d h w d h w description weights (kg/lb) dimensions (mm/inch) d x w x h 5px 1500i rt2u 27.60 / 60.90 522 x 441.2 x 86.2 / 20.6 x 17.4 x 3.4 5px 2000i rt2u 28.50 / 62.80 5px 2200i rt2u 28.50 ...

  • Page 6: 2. Presentation

    Page 6 614-07977-00_en 2. Presentation (1) usb communication port (2) rs232 communication port (3) connector for automatic recognition of optional battery modules (4) slot for optional communication card (5) connector for roo (remote on/off) or rpo (remote power off) control (6) connector for option...

  • Page 7: 2. Presentation

    Page 7 614-07977-00_en english 2. Presentation 2.3 control panel the ups has a five-button graphical lcd. It provides useful information about the ups itself, load status, events, measurements and settings. Power on indicator (green) on battery indicator (yellow) alarm indicator (red) normal mode 10...

  • Page 8: 2. Presentation

    Page 8 614-07977-00_en 2. Presentation 2.4 lcd description as default, or after 5 minutes of inactivity, the lcd displays the screen saver. The backlight lcd automatically dims after 10 minutes of inactivity. Press any button to restore the screen. Operation status load/equipment status normal mode ...

  • Page 9: 2. Presentation

    Page 9 614-07977-00_en english 2.5 display functions press the enter ( ) button to activate the menu options. Use the two middle buttons ( and ) to scroll through the menu structure. Press the enter ( ) button to select an option. Press the button to cancel or return to the previous menu. Menu map f...

  • Page 10: 2. Presentation

    Page 10 614-07977-00_en 2. Presentation description available settings default settings in/out settings load segments - auto shutdown delay [disable] [0s] [1 s] [2 s]…[65354 s] during a power outage, authorises to keep some equipment running while turning off other equipment. This feature allows to ...

  • Page 11: 3. Installation

    Page 11 614-07977-00_en english 3. Installation 3.1 unpacking and contents check 30 35 41 44 40 45 42 36 37 39 38 32 43 46 31 33 34 (30) 5px ups (31) connection cable to ac-power source (5px 2200 and 3000 models only) (32) 2 connection cables for the protected equipment (33) rs232 communication cabl...

  • Page 12: 3. Installation

    Page 12 614-07977-00_en 3. Installation 3.2 installation in tower position note. The two supports for the tower position are used on the rt 2u version only. 3.3 installation in rack position follow steps 1 to 4 for module mounting on the rails. 1 1 3 4 4 3 2 the rails and necessary hardware are supp...

  • Page 13: 3. Installation

    Page 13 614-07977-00_en english 3. Installation 3.4 communication ports connection of rs232 or usb communication port (optional) the rs232 and usb communication ports cannot operate simultaneously. 1. Connect the rs232 (33) or usb (34) communication cable to the serial or usb port on the computer eq...

  • Page 14: 3. Installation

    Page 14 614-07977-00_en 3. Installation 3.5 connection with a flexpdu (power distribution unit) module (optional) 5px flexpdu 43 47 48 49 50 1. 5px 2200i / 3000i: connect the ups input socket (10) to the ac-power source using the cable (31) supplied. 5px 1500i / 2000i: use the power cable of the pro...

  • Page 15: 3. Installation

    Page 15 614-07977-00_en english 3. Installation hotswap mbp module operation 54 55 53 ups start-up with the hotswap mbp module 1. Check that the ups is correctly connected to the hotswap mbp module. 2. Set switch (55) to normal position. 3. Start the ups by pressing the on/off button on the ups cont...

  • Page 16: 4. Operation

    Page 16 614-07977-00_en 4. Operation 4.1 start-up and normal operation to start the ups: 1. Verify that the ups power cord is plugged in. 2. The ups front panel display illuminates and shows eaton logo. 3. Verify that the ups status screen shows . 4. Press the button on the ups front panel for at le...

  • Page 17: 4. Operation

    Page 17 614-07977-00_en english 4. Operation low-battery warning the p and indicator illuminates solid. The audio alarm beeps every three seconds. P the remaining battery power is low. Shut down all applications on the connected equipment because automatic ups shutdown is imminent. End of battery ba...

  • Page 18: 5. Maintenance

    Page 18 614-07977-00_en 5. Maintenance 5.1 troubleshooting operation status possible cause action batteries disconnected the ups does not recognise the internal batteries if the condition persists, contact your service representative the batteries are disconnected verify that all batteries are prope...

  • Page 19: 5. Maintenance

    Page 19 614-07977-00_en english 5. Maintenance 5.2 battery-module replacement safety recommendations the battery can cause electrocution and high short-circuit currents. The following safety precautions are required before servicing the battery components: remove watches, rings, bracelets and all ot...

  • Page 20: 5. Maintenance

    Page 20 614-07977-00_en 5. Maintenance mounting the new battery module carry out the above instructions in reverse order. To ensure safety and high performance, use only batteries supplied by eaton. P take care to firmly press together the two parts of the connector during remounting. P 5.3 maintena...

  • Page 21: 6. Appendices

    Page 21 614-07977-00_en english 6. Appendices 6.1 technical specifications 5px 1500i rt2u 5px 2000i rt2u 5px 2200i rt2u 5px 3000i rt2u 5px 3000i rt3u output power 1500 va 1350 w 2000 va 1800 w 2200 va 1980 w 3000 va 2700 w 3000 va 2700 w ac input power l rated input voltage l input voltage range l i...

  • Page 22: 6. Appendices

    Page 22 614-07977-00_en 6. Appendices backup time time during which the load can be supplied by the ups operating on battery power. Battery test internal ups test to check battery status. Cold start the devices connected to the ups can be started even if ac input power is not available. The ups oper...