Draft - 04 march 2016 mtl gecma rt com module modular communications interface for mtl gecma work stations september 2016 inm mtl gecma rt com rev 2 instruction manual mtl hmi and visualisation.
Draft - 04 march 2016 draft - 04 march 2016 inm mtl gecma rt com rev 2 2 1 foreword please read the entire operating instructions before starting the assembly, connection, installation and commissioning. The gecma rt com module and any associated safe area equipment must be installed or uninstalled ...
Draft - 04 march 2016 draft - 04 march 2016 inm mtl gecma rt com rev 2 3 contents 1 foreword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . ....
Draft - 04 march 2016 draft - 04 march 2016 inm mtl gecma rt com rev 2 4 2 general reference 2 .1 general safety information the following methods are used in this manual to alert the user to important information:- note these are used to give general information to ensure correct operation importan...
Draft - 04 march 2016 draft - 04 march 2016 inm mtl gecma rt com rev 2 5 2 .2 provisions for general operational safety 2 .3 application the mtl gecma rt com module is individually certified and designed for industrial use in the potentially explosive atmospheres of zone 1 and zone 2. The correspond...
Draft - 04 march 2016 draft - 04 march 2016 inm mtl gecma rt com rev 2 6 installation a. The installation must comply with the appropriate european, national and local regulations, which may include reference to the iec code of practice iec 60079-14. In addition, particular industries or end users m...
Draft - 04 march 2016 draft - 04 march 2016 inm mtl gecma rt com rev 2 7 marking each device is marked in compliance with the directive and ce marked with the notified body identification number. This information applies to the mtl gecma rt com module manufactured during or after the year 2015. 2 .6...
Draft - 04 march 2016 draft - 04 march 2016 inm mtl gecma rt com rev 2 8 • the equipment must be operated in accordance with the electrical parameters and other information prescribed in the operating instructions and iecex or ec-type examination certificate. • all earth connections must be made pri...
Draft - 04 march 2016 draft - 04 march 2016 inm mtl gecma rt com rev 2 9 3 overview the mtl gecma rt com module is an ex certified communications interface unit for use in zone 1 and zone 2 hazardous areas. It is intended for use with mtl gecma approved products and is specifically designed to be us...
Draft - 04 march 2016 draft - 04 march 2016 inm mtl gecma rt com rev 2 10 5 installation 5 .1 general information warning! The ‘safety guidelines and provisions’ and ‘installation and connection instructions’ must be studied and strictly adhered to in order to ensure safe and reliable operation. War...
Draft - 04 march 2016 draft - 04 march 2016 inm mtl gecma rt com rev 2 11 5 .3 electrical connections 5 .3 .1 dc power connection the mtl gecma rt com module must be powered from an mtl gecma ws psu power supply module that is normally fitted alongside the rt com module as shown in the picture on th...
Draft - 04 march 2016 draft - 04 march 2016 inm mtl gecma rt com rev 2 12 5 .3 .2 peripheral equipment connections once the power supply has been connected, the remaining connections can be made to the rt com module. These are illustrated in the following diagram and their purpose described below. S...
Draft - 04 march 2016 draft - 04 march 2016 inm mtl gecma rt com rev 2 13 5 .3 .3 connecting the data cable the data cable is a fibre optic cable with optical transmission (foc). The advantage of this cable type is in permitting fast, loss-free, data transmission over long distances. Important: this...
Draft - 04 march 2016 draft - 04 march 2016 inm mtl gecma rt com rev 2 14 6 maintenance at regular intervals, depending upon the particular location of the mtl gecma rt com module, the general state of the unit should be assessed for both its electrical and mechanical condition. The following item c...
Draft - 04 march 2016 draft - 04 march 2016 inm mtl gecma rt com rev 2 15 7 replacing an mtl gecma rt com module in the event that an mtl gecma rt com has to be replaced, this section explains the steps necessary to remove an existing remote terminal communication module and fit a replacement. For f...
Draft - 04 march 2016 draft - 04 march 2016 inm mtl gecma rt com rev 2 16 7 .2 removal of the mtl gecma rt com module the picture below provides a view of the electrical and fibre-optic connectors for the rt com module to be removed. The diagram below reproduces the label attached to the back of the...
Draft - 04 march 2016 draft - 04 march 2016 inm mtl gecma rt com rev 2 17 7 .3 removing the existing mtl gecma rt com module important: ensure that the power to the terminal is switched off and secured against intentional or unintentional reconnection. 1. The power supply module is located to the le...
Draft - 04 march 2016 draft - 04 march 2016 inm mtl gecma rt com rev 2 18 5. All connectors are on the right-hand side of the connector panel and each has a securing tab that must be pressed to allow the connector to be removed. Press each tab and remove the connectors in turn. 6. Remove the main rt...
Draft - 04 march 2016 draft - 04 march 2016 inm mtl gecma rt com rev 2 19 colour code pin assignment function white 22v dc output fused red 5v dc input black 0v input 8. When all connections have been made on the ws psu and rt com module, replace the cover securely using the four screws previously r...
Draft - 04 march 2016 draft - 04 march 2016 inm mtl gecma rt com rev 2 20 appendix a - returns (rma order) dear customer should you find your goods are defective or require a warranty repair, please complete the on-line form on our website at www.Gecma.Com resources/rma to obtain a rma reference for...
Draft - 04 march 2016 draft - 04 march 2016 inm mtl gecma rt com rev 2 21 this page is left intentionally blank.
Draft - 04 march 2016 draft - 04 march 2016 inm mtl gecma rt com rev 2 22 this page is left intentionally blank.
Draft - 04 march 2016 draft - 04 march 2016 inm mtl gecma rt com rev 2 23 this page is left intentionally blank.
Europe (emea): +44 (0)1582 723633 mtlenquiry@eaton.Com the americas: +1 800 835 7075 mtl-us-info@eaton.Com asia-pacific: +65 6 645 9888 sales.Mtlsing@eaton.Com the given data is only intended as a product description and should not be regarded as a legal warranty of properties or guarantee. In the i...