Page 29
weight of the control unit plus batteries can be up
to 11kg.
Connect the battery leads, red to the positive,
black to the negative terminals of the battery.
Connect the other ends of the leads to BATT (item
9 in Figure 3).
Figure 55 Fitting the Batteries
Note: Connecting the battery without mains power
will not start the system. (See “Programming
Before Installation” in the i-on Range Engineering
Guide.)
Step 11. Initial Power-Up
Please see the i-on Range Engineering Guide for
an explanation of bus addressing.
WARNING: During initial power-up all the keypad
sounders, internal loudspeakers and wired sirens
MAY give an alarm tone. If you are working at the
top of a ladder make sure that the sudden noise
does not startle you and cause a fall.
1. Apply mains power to the control unit.
The keypads and internal sounder may give
an alarm tone. The heartbeat LED on the
control unit PCB (item 6 in Figure 3 ) starts
flashing. The navigation keys on any attached
keypad start flashing.
All connected keypads briefly show the
software revision of the keypad itself, followed
by the words “Please wait...” for several
seconds while the control unit scans the bus.
When the control unit has finished scanning
the bus the keypads show:
2. Press and hold keys A and simultaneously
on the keypad that you wish to use for initial
programming. NOTE: Hold the keys down
for at least three seconds.
After a short pause the keypad gives a
confirmation tone. The display briefly shows
the bus address of the keypad. If there are no
other keypads connected to the bus it should
be “b1-d51”(bus 1 device 51). Keypads take
bus device addresses 51 upwards.
If you are installing a UK panel, please go
to step 6.
If you are installing an EUR panel:
The keypad display then shows:
3. Press or followed by to select the
language you wish to use.
From this point on, the display operates in the
selected language. If you want to change the
language later use Installer Menu - System
Options - Language.
The display shows:
4. Press or to show other countries, for
example
5. Press to select the country you want.
The display shows:
6. Press A or B to select either a Partitioned
system or a Part Setting system.
Note: To change to Partition or Part Set mode at a
later date you will have restore factory defaults.
The display shows:
7. Press or to show the Security Grades
available, for example:
8. Press to select the security grade you
intend to use for the system.
The display shows:
9. Press or to show the range of zone
wiring types available, for example:
10. Press to select the wiring type you intend to
use for the wired zones.
Note: This initial choice fixes the wiring type for
the control unit and any attached wired
expanders. If you wish to use a different wiring
type on the expanders then use Installer Menu
–
Detectors/Devices
– Wired Expander after the
initial power up to change the wiring type for each
expander.
The display shows: