Eberle EM 524 89 Assembly And Operating Instructions Manual - Base Temp
Operation:
Range: AUTOMATIC, PERMANENT Default value: AUTOMATIC
With this function, you can switch the heating on continuously, irrespective of the set
temperatures and humidity. The heating remains switched on during an alarm.
Sensor heater:
Range: AUTO, ON
Default value: ON
In Automatic mode the sensor heater is switched off when the heating system is switched
on. In ON mode the sensor heater stays on when the heating system is switched on.
Standard program:
Range: ON, OFF
Default value: ON
The ice detector settings can be reset to defined values here. This does not apply to the
language, application, display and counter menu items. The set language, application and
display are retained and the counter reading can be reset to zero via the appropriate
menu item. You can only select ON with this menu item, as the default program is
disabled by changing to another menu item.
Temp unit:
Range: °C, °F
Default value: °C
Selection of the unit in which temperature values are to be displayed. °C Temperature
values displayed in °C. °F: Temperature values displayed in °F. The selected display is
retained when you revert to the default program.
Language:
Range: GERMAN, ENGLISH, FRENCH, FINNISH, SWEDISH, CZECH,
HUNGARIAN, POLISH, ITALIAN, SPANISH, TURKISH, DUTCH
Various languages can be selected for the ice detector display. German, English, French,
Finnish, Swedish, Czech, Hungarian, Polish, Italian, Spanish, Turkish and Dutch can be
selected. The selected language is retained when you revert to the standard program.
Counter:
00000H00M to 65535H59M
This is the operating hours’ counter for the heating. It is displayed in hours and minutes.
The counter reading is retained when you revert back to the default program. To reset the
counter, select RESET with the “VALUE” button and then press “ENTER” to reset.
The various temperatures are displayed as double-digit values in °C and °F with the
correct sign before them.
For example:
BASE TEMP
–10 °C
or.:
TEMPERATURE
+ 3 °C
The counter reading is displayed in hours and minutes.
For example:
COUNTER 1
00038H25M
This display corresponds to a heating operating time of 38 hours 25 minutes.
7