Air heaters B1L/D1L
Technical Description
Installation instructions
Operating Instructions
Air heaters independent of engine
B1L for petrol
D 1 L for diesel
Specifications
Heating medium
Air
Hot air throughput
1)
100 kg/h ±10
(without counter-pressure)
Heating capacity
1)
1800 W ± 10 11/0
Fuel
B1L:
Gasoline,
(see also page 10)
(Commercial grade)
D1L: Diesel fuel,
(Commercial grade)
Fuel consumption
1)
B1L: 0.24 I/h ± 5%
D1L: 0.21 1/h ± 5
Rated voltage
12 V or 24 V
Operating range:
Lower voltage limits
2)
10 V or 20 V
Upper voltage limit
3)
14 V or 28 V
Electrical power
B1L
consumption
1)
at start 200W±10%
operating 40 W ± 10
D 1 L
at start 12 V = 260 W ± 10
24V=500W±10%
operating 40 VV ±10%
B1L
Cat.
no.
Basic heater
with standard equipment 12V 20 1590 05 00 00
Universal installation kit
20 1575 80 00 00
D 1 L
Cat.
no.
Basic heater
with standard equipment 12 V 25 1384 05 00 00 24V 25
1385 05 00 00
12V 25 1637 05 00004)
24 V 25 1638 05 00004)
Universal installation kit
20 1575 80 00 00
Control elements (to be ordered separately, see page 2). See
Additional Equipment Catalog for other accessories.
Ventilation Possible
with
suitable
circuits
Degree of radio inter-
Remote; additional
ference suppression
interference suppression
measures possible
Weight approx..
3
kg
1)
at rate voltage
2)
an undervoltage safety device built into the control unit
switches off the heaters when at approx.. 10.5 V and 21 V
respectively.
3)
an overvoltage safety device built into the control
unit switches off the heaters when at approx. 15 V and 30 V
respectively.
4)
with glow plug current regulator