Eberspächer B1L Installation Instructions Manual - page 7
Item
Designation
Component
Cat.
No
rating
1
Protective
grid
0.4
20
1465
89
05
00
2
Connection piece, 50 mm dia.
0.4
20 1575 80 08 01
3
Hose
clip,
50
-
70
mm
dia
- 2064
05
00
70
4
Flex. pipe, 50 mm dia. lin. m.
1.0 per m
10 2114 29 00 00
5
Protective grid, 50 mm dia. 0.1
20 1575 89 20 00
6
Hood
0
20
1465
89
00
01
7
Air outlet, rotatable, 50 mm dia.
1.25
20 1575 80 08 00
-
90° bend of flex pipe, 50 mm dia.
0.4
Do not connect too many components. The sum of the component ratings may not exceed the heater rating. See Additional
Equipment Catalog for further parts.
Item
Designation
Component
Cat.
No
rating
1
Protective
grid
0.4
20
1465
89
05
00
2
Connection piece, 50 mm dia.
0.4
20 1575 80 08 01
3
0.3 flexible pipe, 50 mm dia.
0.3
20 2114 29 00 00
4
1.0 m flexible pipe, 50 mm dia.
1.0
20 2114 29 00 00
5
Reduction hood, 50 mm dia.straight
0.0
20 1465 89 00 01
6
2 x 90° bends of flexible pipe
0.8
(0.4 rating for each)
7
Exhauster, rotatable
1.25
20 1575 80 08 00
Sum of component ratings
4.15
7
The sum of the component ratings does not exceed the heater
rating of 10, installation is therefor permissible.
When checking an installation, the average outlet temperature
should not at the outlet point significantly exceed 110°C with
an intake temperature of 20°C. This will ensure that the safety
thermal cutout switch will not respond under normal
operating conditions.
Heating air intake openings shall be arranged in such a
manner that exhaust from the vehicle's engine and from the
heater cannot be expected to be sucked in under normal
operating conditions, and the heating air cannot be
contaminated.
When operating as a recirculating heater, locate the inlet for
the heating air in such a way that the outflowing hot air cannot
be sucked directly in again.