Eberspächer Combitronic CT03C Operating Manual - page 10
Operating Instructions – Deluxe Panel
10
1
To Turn Panel On / Off
Press and hold
for 2 seconds. The panel will be
switched on or off in turn.
The panel uses minimal electrical power and may be
left on, however, turning the panel off will avoid any
accidental key presses.
Setting the Hot Water Mode
Press
to enter the “Settings Menu”. Press until
“Water Mode” is displayed. Press
. Use the or
key to toggle between the three hot water modes.
Diesel
Uses only diesel fuel to heat the
domestic hot water.
230V
Uses only the 230V AC mains hook
up to heat the domestic hot water.
Auto
Uses both diesel fuel and 230V AC
for faster warm up of the domestic hot
water.
Press
to exit.
!
Caution!
Auto and 230V mode should not be selected if the
domestic water system has been drained.
Setting the Heating Mode
Press
to enter the “Settings Menu”. Press until
“Heat Mode” is displayed. Press
. Use the or
key to toggle between the three heating modes.
Diesel
Uses only diesel fuel to heat the
accommodation.
230V
Uses only the 230V AC mains hook
up to heat the accommodation.
Boost
Uses both diesel fuel and 230V
AC for faster warm up of the
accommodation.
Press
to exit.
Please Note!
In 230V AC mode, only 1500W of heat will be available.
Adjusting the Desired Temperature
While in either the Combitronic or Mode screen, press
either or . The desired temperature is adjusted by
one degree higher or lower.
To Start Heating (Hot Water Only)
Press
, the red indicator will illuminate.
Using diesel fuel or 230V AC, the domestic water will
start to heat up. This process should take between
10 and 15 minutes from cold. Once hot an integral
thermostat will monitor the water temperature and re-
heat when required.
To Start Heating (Accommodation)
Press
the red indicator will illuminate.
The heat exchangers within the Combitronic begin to
preheat and therefore a delay should be expected before
the heating fan begins to convey warm air to the outlets.
Using diesel fuel, mains or both, the Combitronic will
begin to heat the accommodation to the temperature
selected. As set point approaches the fan will begin its
regulation phase until the desired temperature has been
reached.
Please Note!
Hot water will be available.
Toggle Display
The “Combitronic Screen” displays the current time and
date. Press the
key and the display will change to the
“Mode Screen”. Now the heating mode, power source
and desired temperature for air heating will be displayed.
After 30 seconds the display will revert back to the
“Combitronic Screen”.
To Stop Heating (Hot Water Only)
Press
, the red indicator will go off.
The Combitronic will cease heating the hot water.
To Stop Heating (Accommodation)
Press
, the red indicator will go off.
After a short cool down cycle, the Combitronic will cease
heating the accommodation.
3C