Eberspächer Combitronic CT03C Operating Manual - Technical Description
Technical Description
6
1
The Combitronic range of heaters are diesel fuelled
blown hot air and hot water heating systems. With
varying outputs, control options and 230v AC devices
there will be a product within the range to suit your
heating needs.
The model type is specified by code and is explained as
follows:
CT
Refers to Combitronic.
03
3.5kW maximum output at 0°C for
accomodation heating.
M
Modular version.
C
Compact version.
S
Standard controls with mode selection and
dial temperature control.
D
Deluxe controls with 230v air heating and full
function control panel.
2
Therefore, a CT03MD is a 3.5kW blown air system
with an additional 230v AC blown air function using the
Deluxe control interface.
All heaters in the range offer the latest PWM technology
for smooth fan control with high efficiency heat
exchangers for fast heat-up times of the interior and hot
water.
Typically, hot water will be achieved after approximately
15 minutes with a recovery time of 10 minutes.
All Combitronic heaters can be used while stationary or
on the move, providing an adequate supply of diesel and
DC electrical power is available.
Technical Specification
CT03
CT03 - D
Air Heating Output (W)
Diesel (maximum)
3,500
3,500
Mains 230v (maximum)
-
1,500
Air Heating Output (W)
Diesel (minimum)
500
500
Mains 230v (minimum)
-
500
Water Heating Output (W)
Diesel (maximum)
1,000
1,000
Mains 230v (maximum)
1,000
1,000
Fuel Consumption (l/hr)
Minimum
0.27
0.27
Maximum
0.62
0.62
Electrical Power Consumption (W)
Minimum
23
23
Maximum
85
85
Electrical Power Consumption (W)
At start
120
120
After Running (heating only)
8
8
Fan Air Throughput (m3/h)
Minimum
50
50
Maximum
260
260
Technical data is based on zero restrictions.