TROUBLE SHOOTING
Unit will not start – there are no audible clicks at startup:
a. The first thing to check is to ensure that the incoming water on
the "right" side of the unit. If the incoming and outgoing are
reversed, the unit will not work. The incoming is on the far right
and the outgoing is in the middle.
b. Check to make sure you have fresh batteries and they are
installed in the correct position
c. Number one reason that the unit does not ignite is that there is
not enough water pressure. You need a minimum of 20 PSI
sustained. Municipal water should supply enough water pressure.
Most 12/18/120 pumps well as long as they are capable of
delivering pressure of 30 PSI or greater.
ADJUSTMENT: Looking up at the bottom of the unit, you will see
two “slits” in the case where the front and back come together.
Locate the water regulator where you will see two Philip head
screws. Take the screw that is furthest on the right (larger screw)
in about a ¼ or ½ turn. This will enable the unit to operate on a
lower water pressure by restricting flow.