2x56W@4Ω 1% THD
2x68W@4Ω 10% THD
2x34W@8Ω 1% THD
2x41W@8Ω 10% THD
98W@ 100Ω 1% THD 100V
98W@ 50Ω 1% THD 70V
Frequency response 15Hz - 25kHz (-3dB)
75Hz - 25kHz (-3dB)
THD+Noise @ 1kHz Full Pwr. SPKR OUT < 0.15%
< 0.07%
Channel crosstalk @ 1kHz
>65dB
Inputs Sensitivity nom/Impedance
0dBV/>20kΩ
Volume adjust
-∞ to +6dBV
High Pass Filter (internal, no removable) NA
70Hz
Signal Noise Ratio >85dB
>70dB
Dante™ input / output
Volume adjust
-∞ to 0dBV
Resolution
24 bits
Dynamic range
100dB
Dante™ audio interface
Dante Network outputs
2
Latency
1 / 2 / 5 ms (selectable)
Connector
1 x RJ45
Cable length between devices
100m CAT5 or CAT5e / CAT6
Priority and input mode
Priority function
Threshold: -30dB
Priority release time (with Fade-in)
Fast: 4seg.
Slow:18 seg.
Miscellaneous
Remote control
Master Volume
Analog. 0 -10V based (RJ45 connector)
Auto standby
Time: 90 seg. (aprox.)
Threshold: -40dBV (L&R)
Signal present
Threshold -40dBV (L&R)
Input select button
Pressed: Dante™ INPUT
Released: Line INPUT
Priority mode button
Pressed: Mode ON
Released: Mode OFF
Supply
DC supply
24V
Mains (using supplied DC adapter)
90-264VAC 50-60Hz
Power consumption
Pink noise, 1/8 power @ 4 ohm 38,9VA / 26,6W
38,4VA / 26,3W
Pink noise, 1/3 power @ 4 ohm 66,4VA / 56,9W
65,4VA / 55,0W
Standby mode (time 2 minutes) 14,7VA / 4,9W
14,3VA / 4,5W
Mechanical
Dimensions WxHxD 200x44x120mm
435x44x120mm
Weight 0,90 kg.