OPERATING INSTRUCTIONS.
Read the entire SAFETY INFORMATION section at the beginning of this manual
including all text under subheadings therein before using this product.
Use this tool for the manufacturer’s intended purpose only. Use other than that
which is described in this manual can result injury or property damage.
1.
Select the appropriate punch, die and draw stud for appropriate size hole.
Do not exceed the rated capacity of this tool; otherwise it will cause a
component failure, which could throw broken parts with great force. Failure
to observe this warning can result injury or death.
2.
Drill a pilot hole by electric drill on the metal sheet, then use a drill bit that is slightly
larger than the draw stud, drill a hole.
3.
Thread the draw stud completely into the ram..
4.
Slide the spacer onto the draw stud to protect the cylinder, and the die after, then let
the metal sheet go through the draw stud by the hole. Lastly thread the punch facing
the steel plate. Make sure the spacer, punch, die and material are as tight as possible
by hand.
An improper setup could cause the components to be damaged.
5.
Pump the pump handle until completely punched.
Do not operate the pump after ram motion stops. Continuing to operate the
pump lever after the ram stops will damage the ram. If the ram stops before
the hole is complete, stop pumping, check that the setup is correct and that
you have not exceeded the tool’s capacity. See the setup instruction.. if
necessary, disassemble the setup and add or remove the spacer.
Make sure the punching cycle is completed during the operation to avoid the
scrap remaining the down punch.
6.
Turn the screw counter-clockwise to release the pressure at the pump.
Do not allow anyone to stand in front of the punch or behind the hydraulic
ram. Ignore this warning can result in injury or damage.
Please refer the illustration below
Test Equipment Depot - 800.517.8431