Eclipse ACC970 Instruction Manual - Acc950 / Acc970
ACC950 / ACC970
V110519
A 18/02 15:45:25
FRI 00001 001
B. Enter/Escape Program Mode
C. Initial Setup
D. Security Trigger Signal
Enter program mode
Input 123456 or PPPPPP (PPPPPP= modified Master Code; Default= 123456)
[e.g.] If the Master Code= 876112, input 876112 → Enter program mode
※
If without any operation for 30 seconds access controller will escape program mode.
Escape program mode
Press continuously → Quit
6
6
8
8
[e.g.] ACC970 is the 8th slave reader under the 16th ACC1000.
Door-H input (door NO. of controller); Door-L input (door No. of the reader).
[e.g.] ACC950 is a controller and its Node ID is 8.
Door-H input ; Door-L input
1
8
Changing the Node ID of Reader
Enter program mode → Parameters[1] → Node ID →
Input New Node ID:1~254(default value: 001)
→
Input: 1~4 to Show Card ID format? (1.No, 2.WG, 3.ABA, 4.HEX) → Input Door number H: 1~254(door
No. of its controllen) → Input Door number L: 1~254(door No. of reader) → Succeeded
3
1
Work Status Code
Date
Time
Serial NO.
User Add.
Week
A: Duty On
B: Duty Off
C: Overtime On
D: Overtime Off
E: Break Out
F: Break RTN
G: Out
H: Return
01: PWD/PIN Error
03: Invalid Card
04: Time-zone Error
11: Normal Access
16: Egress (Request to exit)
17: Alarm
31: Anti-pass back Error
Work Status Code:
Changing the Master Code
Enter program mode → Tools → Master Code → Input the 6-digit new master code → Succeeded
5
2
Restoring Factory Settings
Enter program mode → Parameters[2] → Factory Reset →
select [1: Yes] → Succeeded...
4
9
Enable the Security Trigger signal
Enter program mode → Parameters[1] → Arming Pulse →
Input [10](default value:1000)→ become the Security Trigger signal Output
※
If Request To Exit connect to
[ACC899], the Request To Exit can control the lock immediate.
3
9
Review the old events
Enter program mode → Tools → View Events → the display will show the history events.
5
0
Changing the Language
Enter program mode → Tools → Language → EN → Succeeded...
5
1
1
Adding and Deleting Card
Operation
A. Keyboard Lock/ Unlock
Lock/ Unlock
Hold down and buttons in simultaneously to lock/unlock the keyboard.
Mode4/Mode8
1
Enter program mode → Add/Delete → Add Card > ID →
Input 5-digit user address → Input Site Code → Input Card Code
1
Adding Card by Card ID
1
5
Enter program mode → Add/Delete → Delete > Address →
Input Start address → Input End address
Deleteing User Address
2
1
Enter program mode → User Setting → Password →
Input 5-digit user address → Key in 4-digit PIN
Setting up the password
2
2
Enter program mode → User Setting → Access Mode →
Input 5-digit user address → 1: Card; 2: or PIN; 3: & PIN; 4: Pause;
Setting up the access mode
Mode6
※
In Mode6, user address is card code. Only suspend or recover to add or delete the cards.
Tag Information
SITE CODE
CARD CODE
SITE CODE
CARD CODE
1
2
Enter program mode → Add/Delete → Add > RF Learn →
Input 5-digit user address →
Input Tag Units(pcs) → Close Tag into RF Area to induct.
Adding Card RF Iduction
※
For block
Sequential cards, present the lowest card code card to the controller reader; for block
random cards, present all the cards one by one to the controller reader.
7
1
Enter program mode → Add/Delete → Recover > Address →
Input Start address → Input End address
Adding Card
※
For block
Sequential cards, present the lowest card code card to the controller reader; for block random cards, present all the cards one by one to
the controller reader.
1
3
3
8
Enter program mode → Parameters[1] → Arming PWD →
Input: 0000
Card Only
3
8
Enter program mode → Parameters[1] → Arming PWD →
Key in 4-digit PIN [0001~9999, default value: 1234]
Card and PIN
4
8
Enter program mode → Parameters[2] → Duress Code →
Key in 4-digit PIN [0001~9999, default value: 4321]
Card or PIN
Enter program mode → Add/Delete → Suspend > Address →
Input Start address → Input End address
Deleting Card
※
M6 access mode setting procedure is the same as the arming password/duress code setting procedure in M4.
※
First Update the Firware to 7v4_T2 later