Eclipse ECL-1000 User Manual - page 8
Specification
Maintenance
. Battery
. Wet
. Stop operation
ECL-1000 Users’ Manual_14
15_ECL-1000 Users’ Manual
Range
Accuracy
Resolution
Repeatability
V.O.P (Velocity of Propagation)
Auto V.O.P set
User settable V.O.P
Auto Power Off
Display
Power Supply
Operation time
Line Voltage Detection
Input Protection
Safety (EMC)
Certification and Compliance
Warranty
Size
Environmental
Accessories
Soft Carrying Case (w/belt clip), Test Lead, Manual
Operation : -20℃ ~ 70℃ / Storage : -30℃ ~ 80℃
63 * 140 * 30 mm / 180g (w/batteries)
1 year from date of purchase
Conforms to relevant European Union directives
EN 55011:2009 / A1:2012 / EN 61326-1:2013 /
EN 61326-2-2:2013
DC 48 V
± 250mV / 500kHz
30,000 times with back-light
2 AA(LR6) type battery
128 * 64 Character LCD
Support ( Off, 30min, 1hour, 2 hour )
8ea
Support
1.0 % ~ 99.9 % (In 0.1 % step)
± 0.3 % of reading
1cm
± 1.0 % of reading
3km, Min. distance : 5m
This instrument requires 2 LR6 (AA) type batteries. To prevent unreliable
test results, replace the battery as soon as the battery icon shows no bars
(See “Installing Batteries”) Before you remove the battery door, make
sure disconnect the cable.
If moisture gets inside the instrument, let the instrument dry at ordinary
temperature for 24 hours.
If the instrument stops operating, there are 2 options.
1st option, wait at least 10 seconds the instrument without operating.
If it still does not operate, remove the batteries as described “Installing
Batteries” section, wait at least 5 seconds, then replace the battery. This
resets the instrument. Use the same battery if you know it is good or use
a new battery if you are not sure. If it still does not operate, contact your
reseller or Eclipse Tools Technical Support.