  • Page 1

    In s ta ll a ti o n a n d o p e ra ti o n m a n u a l room air conditioners portable heat pump range eco15p register your air conditioner model information can be found on the ce label. Please register your product online at www.Ecoair.Org. For your future convenience, record the model information b...

  • Page 2

    Congratulations! You have purchased the very latest in room air conditioner technology. Your new ecoair high efficiency room air conditioner will give you many years of dependable service. Many features have been built into your ecoair air conditioner to assure quiet operation, the best circulation ...

  • Page 3

    Bs plug wiring wiring instructions: should it be necessary to change the plug please note the wires in the mains lead are coloured in accordance with the following code : blue - neutral brown – live green and yellow - earth as the colours of the wires in the mains lead of this appliance may not corr...

  • Page 4

    Specification model no. Eco15p cooling capacity 15000 btu/hr 4395watts heating capacity 15000 btu/hr 4395watts power/ampere consumption for cooling 1655 w/ 7.5a power/ampere consumption for heating 1280 w/ 5.9a air volume (max. Speed) 550m 3 /h humidity removal capacity 1.6l/hour power supply 220-24...

  • Page 5

    Before use before use before use before use general safety • only use in the upright position on a flat level surface and at least 50cm from any objects (fig 1&4). • do not place objects on the unit or restrict air inlet/outlet (fig. 2). • closely supervise any children and pets when unit is in use....

  • Page 6

    For maximum efficency • do not exceed the recommended room size. • take into the account the number of people or equipment used in the room as these produces heat and will reduce the cooling effectiveness. • avoid opening doors frequently. • keep curtains of blinds closed during the warmest part of ...

  • Page 7

    Product description product description product description product description front back 1. Control panel 2. Air vent 3. Handle 4. Caster 5. Air filter 6. Air inlet 7. Cord storage 8. Outlet of exhaust air 9. Water stopper / outlet of condensed water accessories 10. Exhaust hose. 11. Pvc strip - f...

  • Page 8

    Installation installation installation installation installation of the exhaust pipe the unit is a portable air conditioner that may be moved from room to room. 1. Using the pvc strip fig.8 • offer pvc strips to the window gap and adjust to size if necessary. • connect one end of the exhaust pipe to...

  • Page 9

    Mounting of the exhaust pipe • use only the hose provided and clip exhaust hose and unit adaptor to the back of the air conditioner. • avoid kinks and bends in the exhaust hose as this will cause expelled moist air to build up causing the unit to overheat and shut down. Fig 8 & 9 show correct positi...

  • Page 10

    Installation of carbon filter 1. Remove the filter frame from the unit. 2. Separate the filter fixer from the filter frame. 3. Remove the active carbon filter from its plastic bag. 4. Insert the active carbon filter into the filter frame. 5. Fix the filter by reassembling the fixer onto the filter f...

  • Page 11

    Operation of the control panel control panel fig.16 1. Speed (ventilation) button 2. Timer button 3. Display window 4. Receiver for remote control 5. Heating operation indicator(optional) 6. Mode (function) button 7. Auto operation indicator 8. Cooling operation indicator 9. Fan operation indicator ...

  • Page 12

    Indicators of the functions in progress come on at the same time. *note! The display window shows the ambient room temperature from 0 o c to 50 o c to turn the unit off, press on/off button again, then close the air louvers. Setting mode/function press mode button to select required working mode: au...

  • Page 13

    3. In sleep mode, the ventilation will be kept at low speed. Re-press the sleep button, the setting temperature and ventilation speed will return to the pre-selected one. 4. In sleep mode, the unit will shut down automatically after running for 12 hours. 5. Please note, the sleep function is not ava...

  • Page 14

    Self diagnosis self diagnosis self diagnosis self diagnosis this machine is equipped with self-diagnosis function. Please contact us if your machine displays “e1” or “e2” codes. Notice ! 1. To prolong the compressor's life, after switching off the unit, please wait for a minimum of 3 minutes before ...

  • Page 15

    Drainage drainage drainage drainage during the process of cooling, some water will be extracted from the air into the unit. Most of the water will be evaporated by the coil for maximum efficiency. However in very warm temperature or humid condition, excessive condensation may occur and will require ...

  • Page 16

    • the drain tube may be extended by adding an extension tube and using a suitable connector. Fig.21 please note 1. The drain must be at or below the outlet level. 2. Flashing comp / ‘full water’ indicator will not function in this mode of drainage. 3. If you want to extend the water tube, you can co...

  • Page 17

    Maintenance maintenance maintenance maintenance always unplug the air conditioner from the mains before cleaning. To maximize the efficiency of the air conditioner, clean regularly. Cleaning the housing use a soft, damp cloth to wipe the body clean. Never use aggressive chemicals, gasoline, detergen...

  • Page 18

    Fault check list fault check list fault check list fault check list the air conditioner does not run is the air conditioner plugged in? Is there a power failure? Is the comp / ‘full water’ indicator flashing? Is the room temperature below the set temperature? The machine seems to do little is there ...

  • Page 19

    Easy to order form for accessories (please complete in block capitals in black ink) full name: previous invoice no.: (if available) model no. Delivery address: telephone no.: email address: signature description product code qty unit price total filters rear filter & fixer 15p-108&109 £14.99 side fi...

  • Page 20

    One (1) year limited warranty save this warranty information ecoair guarantees this product free from defects in materials and workmanship for a period of one (1) year from the date of purchase, limited to parts only. Faults arising from a faulty installation is specifically excluded. This unit must...