Eco Air ECO15P Installation and operation manual

Other manuals for ECO15P: Installation And Operation Manual
Manual is about: Portable Heat Pump Range Local Air Conditioner

Summary of ECO15P

  • Page 1

    In s ta ll a ti o n a n d o p e ra ti o n m a n u a l room air conditioners portable heat pump range local air conditioners eco15p register your air conditioner model information can be found on the ce label. Please register your product online at www.Ecoair.Org. For your future convenience, record ...

  • Page 2

    Congratulations! You have purchased the very latest in room air conditioner technology. Your new ecoair high efficiency room air conditioner will give you many years of dependable service. Many features have been built into your ecoair air conditioner to assure quiet operation, the best circulation ...

  • Page 4

    Specification model no. Eco15p cooling capacity 15000 btu/hr 4395watts heating capacity 11600 btu/hr 3400watts power/ampere consumption for cooling 1655 w/ 7.5a power/ampere consumption for heating 1280 w/ 5.9a air volume (max. Speed) 550m 3 /h humidity removal capacity 1.3l/hour power supply 220-24...

  • Page 5: Before Use

    Before use general safety • only use in the upright position on a flat level surface and at least 50cm from any objects (fig 1&4). • do not place objects on the unit or restrict air inlet/outlet (fig. 2). • closely supervise any children and pets when unit is in use. • this appliance is not intended...

  • Page 6

    For maximum efficency • do not exceed the recommended room size. • take into the account the number of people or equipment used in the room as these produces heat and will reduce the cooling effectiveness. • avoid opening doors frequently. • keep curtains of blinds closed during the warmest part of ...

  • Page 8

    Installation installation of the exhaust pipe the unit is a portable air conditioner that may be moved from room to room. 1. Using the pvc strip fig.8 • offer pvc strips to the window gap and adjust to size if necessary. • connect one end of the exhaust pipe to outlet of exhaust air and the other en...

  • Page 9

    11 12.

  • Page 10

    Installation of carbon filter 1. Remove the filter frame from the unit. 2. Separate the filter fixer from the filter frame. 3. Remove the active carbon filter from its plastic bag. 4. Insert the active carbon filter into the filter frame. 5. Fix the filter by reassembling the fixer onto the filter f...

  • Page 11

    Operation of the control panel control panel fig.16 1. Speed (ventilation) button 2. Timer button 3. Display window 4. Receiver for remote control 5. Heating operation indicator(optional) 6. Mode (function) button 7. Auto operation indicator 8. Cooling operation indicator 9. Fan operation indicator ...

  • Page 12

    Indicators of the functions in progress come on at the same time. *note! The display window shows the ambient room temperature from 0 o c to 50 o c to turn the unit off, press on/off button again, then close the air louvers. Setting mode/function press mode button to select required working mode: au...

  • Page 15

    Drainage during the process of cooling, some water will be extracted from the air into the unit. Most of the water will be evaporated by the coil for maximum efficiency. However in very warm temperature or humid condition, excessive condensation may occur and will require water drainage when tank is...

  • Page 17

    Maintenance always unplug the air conditioner from the mains before cleaning. To maximize the efficiency of the air conditioner, clean regularly. Cleaning the housing use a soft, damp cloth to wipe the body clean. Never use aggressive chemicals, gasoline, detergents, chemically treated cloths, or ot...

  • Page 18

    Fault check list the air conditioner does not run y is the air conditioner plugged in? Y is there a power failure? Y is the comp / ‘full water’ indicator flashing? Y is the room temperature below the set temperature? The machine seems to do little y is there direct sunshine? (please put down the cur...

  • Page 19

    +44 845 388 9313 +44 845 388 0005.

  • Page 20

    +44 845 388 0007.