Eco Range Range cooker Installation Instructions & User Manual

Manual is about: Wood Pellet burning cooker

Summary of Range cooker

  • Page 1

    Installation instructions & user manual wood pellet burning cooker please retain these instructions for future reference..

  • Page 2: Warning

    Warning the eco range cooker is wood pellet burning only, no attempt should be made to burn any other fuel, including all types of coal, grain or seed. Under no circumstances should liquid fuels be added. It is not an incinerator and rubbish including painted, tanalised wood and mdf should not be bu...

  • Page 3: Appliance Details

    ** whilst you can reduce the side gaps right down because the lfh is the cool hopper and the rhs the oven, we recommend a 50mm/2” gap to cupboards. A removable front fill piece can then be used to close the gap. This allows good air circulation and help when moving the cooker for any major maintenan...

  • Page 4

    General use: adjust time clock if fitted to the desired times, (usually the same as you central heating). Leave the cooker on say 100c, the cooker will heat up to the temperature set and maintain that temperature whilst the clock calls for it. To cooker just turn up to you desired temperature say 18...

  • Page 5: Installation Instructions

    4/ inspect all rope and glass seals and replaced as necessary. If the cooker has not been used for a prolonged period, in excess of 6 months, the chimney should be swept prior to use to check for blockages and rubble and debris blocking the flue ways. Note; all solid fuel appliances produce consider...

  • Page 6

    The appliances should not be fitted closer than shown in the chart, from combustible materials, e.G. A wooden fire surround or stud wall. When fitted against a wall made of combustible material e.G. A wooden stud wall with plasterboard, if the distance is less than the safe distance specified, extra...

  • Page 7

    The outside using the manifold system a vent will be required for any extractor fan fitted in the same room or adjacent rooms. Great care must be taken with restaurant/café kitchens which have professional levels of extraction. Chimneys a chimney of minimum 5” diameter (125mm) and a minimum length o...

  • Page 8: Trouble Shooting:

    2/ only top grade pellets should be used, preferable made from virgin soft wood. If hard wood pellets are to be use, a service technician with a gas analyser will be required to possibly adjust the air/fuel ratio. 3/ the hopper will require filling from between every 2 days to every month depending ...

  • Page 9

    Lack of draught : a chimney is like a hot air balloon, the air inside want to rise up as it is hotter that the air outside. The 2 things that determine the performance of a hot air balloon are the size of the balloon, which equates to the height and diameter of your flue, and the temperature of the ...

  • Page 11

    The eco range cooker is designed by thornhill eco design ltd, a designer company from canterbury, uk, that specializes in efficient, clean & green cookers and stoves. Eco range cookers 60 wincheap canterbury kent ct1 3rs www.Ecorangecooker.Co.Uk.