Eco Range Range cooker Installation Instructions & User Manual - Warning
WARNING
The ECO range cooker is wood pellet burning only, no attempt should be made to burn any
other fuel, including all types of coal, grain or seed. Under no circumstances should liquid
fuels be added. It is not an incinerator and rubbish including painted, tanalised wood and
MDF should not be burnt in this appliance.
Any attempt is dangerous and will invalidate any guarantees immediately.
Technical data
All built to EN13240 DEFRA approved
Efficiency
82%
CO concentration
@13% Oxygen
0.1%
Fuel
Class A pellet 6-8mm diameter, see
burner manual for details.
Weight in kg
680
kg
kW output intermittent 14kW
Air vent requirement
An air vent is required or direct connection to out
side
Minimum flue draught
mm H
²
O
0.8mm
Flue gas temperature
Spigot Temp.
185 °C
241 °C
Flue size
Min. chimney diameter
Max. chimney diameter
125 (5”)
125 (5”)
150mm (6”)
Minimum distance to
combustible materials
300cm behind (2ft).
20mm at side (3/4”) **
Max. Hearth temp.
Min. Hearth thickness
12mm