Ecobee SMART Installation Manual - page 18
low Temperature Alert Select this to set the
temperature at which the Smart Thermostat will
generate a Low Temperature Alert. The range can be:
Off – no alert will be generated
Set temperature range of 35 – 68°F (1.5 – 20°C).
High Temperature Alert Select this to set the
temperature at which the Smart Thermostat will generate
a High Temperature Alert. The range can be:
Off – no alert will be generated
Set temperature range of 76 – 104°F (24.5 – 40°C).
low Humidity Alert Select this item to set the humidity
level at which the Smart Thermostat will generate a Low
Humidity alert. The range can be adjusted to:
Off – no alert will be generated
Set humidity range of 5 – 95% R.H. in 5% increments
High Humidity Alert Select this item to set the humidity
level at which the Smart Thermostat will generate a High
Humidity alert. The range can be adjusted to:
Off – no alert will be generated
Set humidity range of 5-95% R.H. in 5% increments
Auxiliary Heat Run-time Alert (optional)
In a heat pump with auxiliary heat configuration, you
can program the Smart Thermostat to generate an alert
if the auxiliary heat runs for more than this programmed
amount of time during a 24-hour period.
Auxiliary Outdoor Temperature Alert (optional)
In a heat pump with auxiliary heat configuration, you can
program the Smart Thermostat to generate an alert if the
auxiliary heat is called for when the outdoor temperature
exceeds this programmed set point (this feature requires
an internet connection to function properly)
Enable Alerts to be displayed on console
Select No, if you do not want any of the alerts to be display
on the touch screen interface. Alerts will continue to be
displayed on the web portal and sent via email.
Enable Heating and Cooling Alerts
Select No, if you do not want the Thermostat to generate
the System Failed to Heat or Cool alerts. If disabled, these
alerts will not be shown on the Thermostat or web portal
and no emails will be sent.
31 Configuring The Smart Thermostat
List of Alerts
Below is a complete list of alerts. Depending on your
configuration, some of these may not apply to your system.
low Battery
Furnace Air Filter
Ventilator Filter
uV lamp
Humidifier Filter
Comms fault
low Temp. Alert
High Temp Alert
low Humidity Alert
High Humidity Alert
Heat Not
Responding
Cool Not
Responding
Input 1
Input 2
Maintenance
Reminder
Auxiliary Heat
Run Time
Auxiliary Outdoor
Temperature
The battery in your Thermostat will need
to be changed soon.
Your furnace filter needs to be
cleaned/changed.
Your ventilator filter needs to be
cleaned/changed.
Your UV lamp needs to be changed.
Your humidifier pad needs to be
cleaned/changed.
There is no communication between the
Thermostat and the Equipment Interface
module.
The temperature in the home is too low.
The temperature in the home is too high.
The humidity in the home is too low.
The Humidity in the home is too high.
The system has failed to heat the home.
The system has failed to cool the home.
Used if this input is programmed to
generate an alert.
Used if this input is programmed to
generate an alert.
You are due for regular maintenance.
Your auxiliary heat source is running
too often.
Your auxiliary heat source is running
at higher than expected outdoor
temperatures.
Configuring The Smart Thermostat
32