EcoQuest Eagle 2500 Owner's Manual - Maintenance
8
MAINTENANCE
Periodic maintenance is required to insure that the Eagle 2500 operates properly.
A severely polluted environment can foul an ozone plate in as little as two weeks
or as long as a year. Shown here are basic maintenance procedures that should be
carried out to keep your unit running at top performance.
Rear lint-screen filter cleaning:
You have two options to clean the lint screen:
• When visibly dirty, simply remove the lint screen and with a hand-held vacuum
remove the heavy particulate from the screen. This method will extend the life of
the filter.
- OR -
• When visibly dirty, remove the lint screen from the back of the unit and wash in
hot water, brushing gently with a toothbrush to remove particulate. Allow to dry
prior to re-installing the lint screen.
Ozone Plate
Carefully remove the glass
ozone plates (a,b & c) from
the card cage by grasping
the middle of the edge
nearest to you, and slowly
pulling straight out.
Clean the ozone plate with
hot water and ammonia.
Dry completely using a hair
dryer if necessary. Reinstall ozone plates. Be sure to check
that the electrical tabs are in contact with the plate.
Plate Card Cage
Also be sure to clean the stand-offs at the corners of
the ozone plate card cage. (A cotton swab with alcohol
works well.)
Fan Blade and Front Grill
Wipe off fan blade and front grill if dirty with damp
washcloth. The fan requires no maintenance (with
the exception of the first time it is used, when it may
be necessary to give it a gentle push to get it started).
If the fan squeaks, a drop of lightweight oil may be
needed on the fan shaft.