EcoSpring ES190 Installation And Owner's Manual

Other manuals for ES190: Installation & Owner's Manual
Manual is about: All In One Air-source Heat Pump Water Heater

Summary of ES190

  • Page 1

    Installation & owner’s manual all in one type air-source heat pump water heater ecospring es190 thank you very much for purchasing our product, before using your unit, please read this manual carefully and keep it for future reference..

  • Page 2: Warning!

    Es300 installation & owner’s manual 2 if you can’t make sure that your house power supply is earthed well, please don’t install the unit. The unit must be installed by a licensed tradesperson and in accordance with: • ecospring installation instructions. • as/nzs 3500.4-”national plumbing and draina...

  • Page 3

    Es300 installation & owner’s manual 3 parts names note the pictures in this manual are for explanation purpose only. They may be slightly different from the heat pump water heater you purchased (depending on model). Fan assy ptr valve top cover evaporator filter magnesian stick rear cover front cove...

  • Page 4

    Es300 installation & owner’s manual 4 3 installation & ownerʻs manual contents page warning 2. Safety information please read thoroughly all of the instrucitons before installing or operating the unit. The following safety warnings are very important, always read and obey all safety symbols: ● the u...

  • Page 5

    Es300 installation & owner’s manual 5 4 installation & owner‘s manual table 3-1 accessory name qty. Sharp purpose 1 owner’s & installation manual installation and use instruction this manual 1 drain pipe for water condensation use for draining the condensate water (has been connected to the lower co...

  • Page 6

    Es300 installation & owner’s manual 6 5 installation & ownerʻs manual 3.4 if installed in inclosed space the water heater must be located in a space >15m³, and must have unrestricted air flow. As an example, a room that has an 2.5 tall ceiling and is 3 meter long by 2 meter wide would contain 15m³ ....

  • Page 7

    Es300 installation & owner’s manual 7 6 installation & ownerʻs manual 4. Installation 3) ifter conection of the water system piping work, turn on the cold water inlet valve and hot water outlet valve and bleed all air from the tank. When water flows smoothly out from water outlet pipe(tap water outl...

  • Page 8

    Es300 installation & owner’s manual 8 7 installation & ownerʻs manual 4.3.1 electric wiring illustration caution 4.3 electric connection fig.4-2 50mm larger than the dia. Of unit max. 22mm heat pump water heater warning 4.4 installation checklist 4.4.1 location 1) the flooring beneath the water heat...

  • Page 9

    Es300 installation & owner’s manual 9 installation & ownerʻs manual 8 5.1 operation steps 5. Operating instructions water filling hot water outlet close water out when water flows out from the water outlet, the tank is full. Turn off the hot water outlet valve and water filling is finished. Open ope...

  • Page 10

    10 9 installation & ownerʻs manual fig.5-2 emptying drainpipe shut-off valve close after emptying, please replace the nut of drainpipe. 5.2 trial- running 5.2.1 check list before commissioning. 1) check list before trial-running. 2) correct installation of the system. 3) correct connection of water/...

  • Page 11

    Es300 installation & owner’s manual 11 10 installation & ownerʻs manual note while the ambient temperature is below 5℃, heat pump efficiency will decrease dramatically, the unit will automatically shift to e-heater mode. ⑤ about tco and tod the power of compressor and e-heater will be automatically ...

  • Page 12

    Es300 installation & owner’s manual 12 11 installation & ownerʻs manual 6. Operation 6.1 control panel explanation 6.2 display explanation fig. 6-1 display operation fig.6-2 ① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ 10 11 12 13 14 16 15 17 18 19 11 10 12 13 ⑤ ⑥ ⑦ ⑨ ⑧ water temp will be displayed all the time. Shows water t...

  • Page 13

    Es300 installation & owner’s manual 13 12 installation & ownerʻs manual fig. 6-3 6.2.1 operation interface 20 21 22 23 27 24 25 26 28 table 6-2 21 20 23 22 24 mode selection press button to select operation mode. The the unit can heat water only by heat pump system in this mode. The suitable operati...

  • Page 14

    Es300 installation & owner’s manual 14 13 installation & ownerʻs manual 25 26 set timer-time on only time on only: automatically operate once between the setting of the clock and the last 24 hours. Cancel timer-time on only in the unlocked state, press the button for 3 canceled. Set timer-time on & ...

  • Page 15

    15 installation & ownerʻs manual 6.3 combination button 7. Trouble shooting 7.1 non-error tips q: why canʼt the compressor start immediately after setting? A: unit will wait for 3 min to balance the pressure of system before starting compressor again, it is a self protection logic for the unit. Q: w...

  • Page 16

    Es300 installation & owner’s manual 16 15 installation & ownerʻs manual the diagnostic codes listed above are the most common. If a diagnostic code not listed above is displayed, contact residential technical assistance referencing the number on the front of this manual. Note 7.5 error code shooting...

  • Page 17

    Es300 installation & owner’s manual 17 16 installation & ownerʻs manual 8.2 recommended regular maintenance table checking item checking content checking frequency action 1 air filter (inlet outlet) every month clean the filter 2 anode rod every half year eplace if required 3 inner tank every half y...

  • Page 18

    Es300 installation & owner’s manual 18 17 installation & owner‘s manual 9. Specifications the test conditions: ℃ water temperature from 15 up to 45℃. Model high-pressure protector, over-load protector, 134a(0.8kg) protection compressor power outlet water temp. Water side exchanger inlet pipe dia. Ou...