3.15.2 Symbols
3.16 Description of Alarms
WARNING
REASON
SOLUTION
SMOKE PROBE ALARM
• Fault in the sensor recording flue
temperature
• CONTACT YOUR LOCAL SERVICE TECHNICIAN.
• Sensor is faulty or disconnected
HOT SMOKE ALARM
• Smoke sensor detects a
temperature over 280ºC
• Press the off button and repeat switching on the stove.
• IF THE PROBLEM CONTINUES, CONTACT YOUR LOCAL
SERVICE TECHNICIAN.
NO IGNITION ALARM
• The pellet hopper is empty
• Check whether there are pellets in the hopper and refill if
necessary. IF THE PROBLEM CONTINUES, CONTACT
YOUR LOCAL SERVICE TECHNICIAN.
• Firebox is dirty
• Switch fire off, empty firebox and try to light it again. IF
THE PROBLEM CONTINUES, CONTACT YOUR LOCAL
SERVICE TECHNICIAN.
PELLETS HAVE RUN OUT
ALARM
• The pellet hopper is empty
• Fill the tank with pellets and carry out the automatic auger
loading procedure.
RESET THERMAL ALARM
• Thermostat sensor records
a temperature above the trip
threshold.
• Reset the thermostat and switch the fire back on. IF
THE PROBLEM CONTINUES, CONTACT YOUR LOCAL
SERVICE TECHNICIAN.
DEPRESSION ALARM
• The combustion chamber is dirty
• Follow the cleaning operations of the stove as per the
instructions manual
• The flue is blocked
• Check that the flue is clear and clean
• The vacuum switch is
malfunctioning
• Contact local Service Technician
THERMAL ALARM WITH
RESET
• The thermostat with manual reset
has intervened
• Reset the thermostat pressing the button on the back of the
stove (see Figure below this table)
• The centrifugal fan is defective
• Contact local Service Technician
• Combustion in the fire pot is not
optimal
• Switch off the stove, clean the fire pot and regulate
combustion with the setting of the pellets
WATER PRESSURE
ALARM
• Water pressure is too high or too
low.
• Refill the water or bleed it to return the pressure to normal
values. IF THE PROBLEM CONTINUES, CONTACT YOUR
LOCAL SERVICE TECHNICIAN.
BLACK OUT ALARM
• There is a power black out while
the fire is being used. When the
power comes back on the display
will indicate “BLACK OUT”.
• The smoke fan will automatically switch to maximum speed
and the auger will switch off. When the flue temperature
goes below the ignition threshold, the fire will start the
ignition process.
VENTILATION
• The fire is in cooling phase.
• Wait until flue temperature goes below the minimum
operating threshold before attempting to re-ignite.
EVERY ALARM CONDITION CAUSES THE FIRE TO SWITCH ITSELF OFF IMMEDIATELY
SYMBOL
DESCRIPTION
SYMBOL
DESCRIPTION
Chronothermostat On
Winter Setting On (Always)
Resistance On
Three-Way Valve Positioned
On Radiators
C
Water Temperature Lower Than
Set Temperature
P
Water Pressure Anomaly
P
Pump On