Ecotricity ECO1800S Owner's Manual - page 13
24
23
IMPORTANT: The Eco1800S Solar Generator’s PVCC will be damaged if
connected to a “24V” solar panel, or any source that exceeds 25 VDC.
NOTE: A “12V” solar panel, under Open Circuit conditions and sunlight
exposure can typically produce 23 volts. Refer to the specifications label on
the solar panel before connecting. Do not connect the PVCC to a PV source
capable of delivering more than 8 amps.
NOTE: It is recommended to always charge the internal battery to a
100% state-of-charge, as shown by a steady green PVCC status LED,
and avoid deficit (or partial) charging. Deficit charging reduces a battery’s
useful service life.
Ensure that the PV solar panel is exposed to sufficient direct sunlight and is
producing sufficient power throughout the day for optimum energy harvest
and battery charging.
Power Consumption
of Loads
Up to 1800W
To check the total power consumption of the products plugged into
Eco1800S Solar Generator during backup power mode, press the Select
button and view the Output Power (W) on the screen.
To test the Eco1800S Solar Generator backup power capabilities after
installing the unit, unplug the AC power cord to simulate a power outage.
Ensure the products connected to the Eco1800S Solar Generator continue
operating. You can test the surge capabilities of the Eco1800S Solar Generator
by turning connected products on and off while the unit is unplugged. If
products fail to operate or the screen shows an error code, see
“Troubleshooting”.
Cordless Phone
Cell Phone
Internet Modem
Inkjet Printer
Clock Radio
Laptop Computer
20” LCD Monitor
Table Lamp
13” TV
Desktop Computer
8.8 cu. ft. Freezer
18 cu. Foot Fridge
Sump Pump 1/2 HP
Microwave
40
20
15
50-75
10
20-140
52
40
60
80-450
200
500
500 1/4HP
900-1600
12.5 Hrs
25 Hrs
33 Hrs
46 Hrs
50 Hrs
2-25 Hrs
7.5 Hrs
12.5 Hrs
11 Hrs
15 min-6 Hrs
1Hr
15 min
15 min
5-12 min
Over 1800W
No. Supplementary
protector may trip.
No. Overload
shutdown.
Yes
Yes (up to 1440 W
continuous backup
power mode)
Normal Operation
with Utilty Power
Ability to Provide
Backup Power
Product
Watts
a
Run Time
b
AC POWER CAPABILITIES
RUN TIME ON TYPICAL PRODUCTS
Laptop, Inkjet Printer, Cordless
Phone, Internet Modem
Desktop Computer, 17” LCD
Monitor, Inkjet Printer,
Internet Modem, Cordless
Phone
Cordless Phone, 13” TV, Clock
Radio, Table Lamp
up to 3 Hrs
up to 1 Hr
up to 3 Hrs
Product
Run Time
b
RUN TIME ON TYPICAL PRODUCTS
The Eco1800S Solar Generator includes a 12V DC power port for operating
common DC auto accessories up to 12 amps from the internal 12-volt
battery. If the 12V DC power port is overloaded a protective internal
breaker will open (interrupt) current flow. When the overloading accessory
is disconnected, the breaker will automatically re-close (reset) within a
few minutes.
12V DC POWER PORT
IMPORTANT: When powering the 12V DC accessory, do not allow the
Eco1800S Solar Generator internal battery to be discharged completely
(i.e., 0% state-of-charge) which can permanently damage the internal battery.
To avoid over-discharging the internal battery, do not leave any DC accessory
including mobile phone chargers or other portable appliances permanently
connected to the Eco1800S Solar Generator’s 12V DC power port.
See also Warning below.
NOTE: The Battery Charge (%) reading on the top panel display
(when turned on) is only accurate after the Eco1800S Solar Generator
internal battery has been resting (not charging or discharged) for at least
30 minutes.
a. Average power consumption as measured on loads tested under typical operating conditions. Rated power
may differ from average power consumption.
b. Run times are typical, not minimum. Actual run time may vary.