EcoWater 7283560 Owner's Manual - page 16
15
Features/Options
ECOWATER
S Y S T E
M S
VIEW DAYS TO RECHARGE -- This view only dis-
play shows the number of days the softener will run
before recharging. This display shows only if “OFF”
is not the hardness setting.
Press and hold the SELECT keypad to display the
following screen. Press the SELECT keypad twice
more to display the View Days to Recharge screen.
The default settings for backwash and fast rinse
cycles of regeneration are factory set for maximum
performance of the softener. Use the following pro-
cedures to check for correct cycle times, or to
change if desired. However, only trained technicians
should change the time settings.
ADJUSTABLE BACKWASH -- Press and hold the
SELECT button until the display shows “000----”,
then press the SELECT button three times to ad-
vance to the Backwash time adjust screen. Default
values for Model ESS 2000R30 is 8 minutes, and for
Model ESS 2002R40 default is 12 minutes.
Model ESS 2000R30
Model ESS 2002R40
Using the UP or DOWN keypads, adjust the back-
wash time from 0 minutes to 60 minutes.
ADJUSTABLE FAST RINSE -- Press and hold the
SELECT button until the display shows “000----”,
then press the SELECT button four times to ad-
vance to the Fast Rinse time adjust screen. Default
values for Model ESS 2000 R30 is 2 minutes, and for
Model ESS 2002 R40 default is 3 minutes.
Model ESS 2000R30
Model ESS 2002R40
Using the UP or DOWN keypads, adjust the fast
rinse time from 0 minutes to 60 minutes.
TIMER “POWER OUTAGE MEMORY” -- If electrical
power to the timer is lost, memory built into the timer
circuitry will keep all settings for at least 6 hours. The
display is blank and the softener will not regenerate.
When electrical power is restored, one of two things
will happen.
1. The present time of day will show steady, meaning
the timer has not lost time.
2. The display will show a time, but it will be flashing.
The timer memory did not keep the time setting and
must be reset (page 13). If you do not reset the time,
regenerations will most likely be at the wrong time of
day.
NOTE: The flashing display is to remind you to reset
the timer.
NOTE: If the unit was regenerating when power was
lost, it will now finish the cycle.