Service Information
ECOWATER
S Y S T E
M S
3 -- Valve Bypass
OUTLET
VALVE
INLET
VALVE
BYPASS
VALVE
water
flow
to conditioner
from conditioner
D
for SERVICE:
-- Open the inlet and outlet valves.
-- Close the bypass valve.
D
for BYPASS:
-- Close the inlet and outlet valves.
-- Open the bypass valve.
EcoWater Bypass Valve
CAUTION: ALWAYS relieve water pressure in the softener, as follows,
before removing parts from the valve or resin tank.
DE--
PRESSURIZE
1. Put bypass valve(s) in bypass position.
2. Do Manual Advance step 1 -- 2, page 24 (fill water to brine tank will depressurize the
resin tank).
PRESSURIZE
1. Put bypass valve(s) in service position.
2. Do Manual Advance steps 3 -- 7, page 24, to return unit to service.
ALTERNATE METHOD
3--VALVE BYPASS
ECOWATER BYPASS VALVE
DE--PRESSURIZE
1. Close the INLET valve.
2. Open HOT and COLD conditioned water
house faucets.
3. Close the OUTLET valve and open the
BYPASS valve.
4. Close all house faucets.
PRESSURIZE
1. Open HOT and COLD house faucets.
2. Close the BYPASS valve and open the
OUTLET valve.
3. Slowly, open the INLET valve.
4. Close all house faucets
DE--
PRESSURIZE
1. Close the house main water supply valve.
2. Open HOT and COLD conditioned water
faucets.
3. Push the bypass valve handle to bypass
position.
Note: For hard water bypass to house fau-
cets, reopen the main water supply valve.
PRESSURIZE
1. Open HOT and COLD house faucets
(main water supply valve open).
2. Pull the bypass valve handle to service
position.
3. Close all house faucets.
PUSH IN
for bypass
PULL OUT
for service
TROUBLESHOOTING
ALWAYS MAKE THE INITIAL CHECKS FIRST
INITIAL CHECKS:
1. Does the time display show the correct time of
day?
...If display is blank, check power source to the soft-
ener.
...If time is flashing, power was off for over six hours.
The unit resumes normal operation, when power re-
turns, but regenerations occur at the wrong time.
...If an error code shows in the display (example:
Err03), go to Automatic Electronic Diagnostics, be-
low.
2. Plumbing bypass valve(s) must be in service
position (all the way open or closed, as applies).
3. Inlet and outlet pipes must connect to the osftener
inlet and outlet respectively.
4. Is the transformer plugged into a ‘‘live’’, grounded
wall outlet?
5. The valve drain hose must be free of kinks and
sharp bends, and not elevated over 8’ above the
floor.
6. Is there salt in the brine tank?
7. Is the brine tubing connected? See Figure 9, page
10.
If you do not find a problem after making the initial
checks, do the Manual Advance Diagnostics, page
24.