EcoWater ECR 3000R20 Owner's Manual - page 15
14
ECOWATER
S Y S T E
M S
Faceplate Controller, Features/Options
Primary Menu, continued
Remote Status: Enter Primary Menu. Press the (↑) or (↓) keypads until cur-
sor is next to Remote Status. Press the SELECT/EXIT ( ↵ ) keypad. The
current remote status is displayed.
Send E.A.S.E. Message: Enter Primary Menu. Press the (↑) or (↓) keypads
until cursor is next to Send E.A.S.E. Message. Press the SELECT/EXIT (↵)
keypad. The unit will automatically start sending E.A.S.E. message and
show a progress bar on the display. See page 18.
Advanced/Service: By entering these menus, a warning screen will first be
displayed. Only technicians or knowledgeable users should use these me-
nus.
ADVANCED / SERVICE MENU
The following is a description of the options in the Advanced/Service Menu. To enter any of the following me-
nus, press SELECT/EXIT (↵) to enter Primary Menu. Press the (↑) or (↓) keypads until cursor is next to Ad-
vanced/Service. Press the SELECT/EXIT ( ↵ ) keypad to enter this menu. Warning screen will show, press
the (↑) keypad to continue. To exit to Normal Screen Views move square cursor (J) to EXIT, which appears
at either the top or the bottom of this menu. If no keypad has been pressed display will show for 4 minutes
before returning back to the Normal Screen Views.
Set Language: Press the (↑) or (↓) keypads until cursor is next to Set Lan-
guage. Language can be changed from English to Spanish or French.
Test Remote: Press the (↑) or (↓) keypads until cursor is next to Test Re-
mote and press SELECT/EXIT ( ↵ ). At set up, the unit will send a signal
to the remote every 3 seconds to allow for correct positioning of remote
monitor. Press SELECT/EXIT ( ↵ ) to exit. See page 16 for information on
the Remote Monitor.
Set Low Salt Alert: Press the (↑) or (↓) keypads until cursor is next to Set
Low Salt Alert and press SELECT/EXIT ( ↵ ). Use the (↑) or (↓) keypads
to change Alert Level. At this level the controller will signal that salt needs
to be added to the conditioner brine tank. Press SELECT/EXIT (↵) to exit.
NOTE: This warning will indicate the softener’s inability to reduce barium
& radium 226/228 effectively. Changing the Low Salt Alert to less than 2 will
void the proper function of this indicator.
Efficiency Mode: Press the (↑) or (↓) keypads until cursor is next to Effi-
ciency Mode and press SELECT/EXIT ( ↵ ). Default is Auto Adjusting
which has a minimum efficiency of 3350 grains/lb of salt. Use the (↑) or (↓)
keypads to change to either High Capacity which sets the regeneration salt
doses that are increased by a certain % to handle applications requiring 1.5
PPM (parts per million) or less soft water, or to handle special cases such
as low leakage requirement or problem water conditions; and Salt Efficient
which operates at a minimum of 4000 grains/lb of salt. Changing this setting
will prompt a warning that changes could affect performance. Press SE-
LECT/EXIT (↵ ) to exit.
NOTE: California regulations require the Efficiency Mode to be ON for sale
in California.
continued