EcoWater ESD 2502R30 Owner's Manual - page 3
3
SAFETY GUIDES
Follow the installation instructions carefully. Failure to install the EcoWater softener properly
voids the warranty.
Before you begin installation, read this entire manual. Then, obtain all the materials and tools you will need to make
the installation.
Check local plumbing and electrical codes.
The installation must conform to them. In Massachusetts, plumbing
codes of Massachusetts shall be adhered to. Consult with your licensed plumber.
Use only lead--free solder and flux
for all sweat---solder connections, as required by state and federal codes.
Use care when handling the EcoWater softener. Do not turn upside down, drop, or set on sharp protrusions.
Do not locate the EcoWater softener where freezing temperatures occur. Do not attempt to treat water over 120° F.
Freezing, or hot water damage voids the warranty.
Avoid installing in direct sunlight. Excessive sun heat may cause distortion or other damage to non---metallic parts.
The EcoWater softener requires a minimum water flow of 3 gallons per minute at the inlet.
Maximum allowable inlet
water pressure is 125 psi.
If daytime pressure is over 80 psi, nighttime pressure may exceed the maximum. Use a
pressure reducing valve if necessary. (Adding a pressure reducing valve may reduce the flow.)
The EcoWater softener works on
28V DC
electrical power, supplied by a direct plug---in power supply (included). Be
sure to use the included power supply and plug it into a nominal
120V, 60 Hz
household outlet that is in a
dry location
only
, grounded and properly protected by an overcurrent device such as a circuit breaker or fuse.
This system is not intended to be used for treating water that is microbiologically unsafe or of unknown quality without
adequate disinfection before or after the system.
European Directive 2002/96/EC requires all electrical and electronic equipment to be disposed of according to
Waste Electrical and Electronic Equipment (WEEE) requirements. This directive or similar laws are in place nation-
ally and can vary from region to region. Please refer to your state and local laws for proper disposal of this equipment.
DIMENSIONS
IN
OUT
32--- 1/2”
IN --- OUT
14”
20”
IN --- OUT
14”
14”
C
B
16”
16”
36--- 9/16”
32”
ESD 518
IN
OUT
A
ESD 2502R30
ESD 2502R39
A
B
C
MODEL
NOMINAL RESIN TANK SIZE
A
B
C
ESD 518
8” DIA. X 35”
3---3/8”
38--- 1/8”
45”
ESD 2502R30
8” DIA. X 40”
3---3/8”
41.6”
48.75”
ESD 2502R39
10” DIA. X 47”
3---3/4”
49.8”
56.6”