EcoWater ETF AIV-10 Owner's Manual

Other manuals for ETF AIV-10: Owner's Manual
Manual is about: EcoWater Systems Air Aspirated Iron Filter

Summary of ETF AIV-10

  • Page 1

    Owner’s manual how to install, operate and maintain your ecowater systems air aspirated iron filter models etf aiv-10 etf aiv-12 7336313 (rev. A 12/10/12) ecowater systems llc p.O. Box 64420, st. Paul, mn 55164-0420 1-800-86water designed, engineered & assembled in the u.S.A..

  • Page 2

    2 ecowater s y s t e m s table of contents table of contents page specifications & dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 inspect shipment . . . . . . . . . . . . . . . . . . . . . . . . . . ....

  • Page 3

    3 ecowater s y s t e m s specifications & dimensions side view front view top view 14" 14" in out 3-3/4" in - out 39-1/4" 44-3/4" etf aiv-10 etf aiv-12 nominal mineral tank size 10” dia. X 47” tall 12” dia. X 54” tall a 57” 62-1/2” b 50” 55-3/4” fig. 1 3-3/4” 14” 14” front view side view top view ou...

  • Page 4

    Recommended maximum allowable inlet water pressure is 80 psi. Use a pressure reducing valve if necessary. Be sure the addition of a pressure reduc- ing valve will not reduce the flow to less than the 5 gallons per minute needed for backwash. This filter controller works on 24 volt, 60 hz electri- ca...

  • Page 5

    5 ecowater s y s t e m s before starting installation where to install the filter = place the filter as close as possible to the pressure tank (well system) or water meter (city water). = place the filter as close as possible to a floor drain, or other acceptable drain point (laundry tub, sump, stan...

  • Page 6

    Ecowater s y s t e m s typical installation illustrations 6 fig. 4 drain fitting valve drain hose valve drain hose 1-1/2” air gap 1-1/2” air gap 1-1/2”” air gap 1-1/2” air gap laundry tub sump stand pipe floor drain to standpipe, sump, laundry tub or other suitable drain. 5/8” i.D. (minimum) copper ...

  • Page 7

    7 1. Turn off water supply a. Close the main water supply valve near the well pump or water meter. B. Shut off the electric or fuel supply to the water heater. C. Open high and low faucets to drain all water from the house pipes. 2. Install bypass valve and/or copper tubes: a. If installing a single...

  • Page 8

    8 ecowater s y s t e m s installation b. Place bypass valve(s) into “bypass” position. On a single valve, slide the stem inward to bypass (see fig. 4 on page 6). On a 3 valve system, close the inlet and outlet valves, and open the bypass valve (see fig. 3 on page 6). C. Fully open the house main wat...

  • Page 9

    9 ecowater s y s t e m s description of operation & sanitizing service water enters the filter and passes through air captured at the top of the mineral tank. Dissolved iron, manganese and sulphur are oxidized and then removed by the media in the tank. When the system recharges, it first backwashes ...

  • Page 10

    10 ecowater s y s t e m s programming the electronic controller fig. 12 up button down button display recharge button select button controller settings required upon installation, and after an extended power outage. When the transformer is plugged into the electrical outlet, a model code (haaif) and...

  • Page 11

    11 ecowater s y s t e m s programming (continued) & controller features / options c. Set recharge start time 1. If you completed the previous step, the words “recharge time" should show in the display (see figure 16). Otherwise, press the select button several times until they do. 2. The filter’s de...

  • Page 12

    12 ecowater s y s t e m s controller features / options (continued) recharge cycle time adjustments the default setting for backwash and aspirate times of the recharge cycle are factory set for maximum performance of the filter. Use the following proce- dures to check for correct cycle times, or to ...

  • Page 13

    13 ecowater s y s t e m s features / options (continued) & routine maintenance fig. 23 fig. 24 4. Chemical feeder trip volume: if you have set the auxiliary output control to cf (chemical feeder), you will need to set the volume of water which must flow past the turbine before the auxil- iary output...

  • Page 14

    14 manually initiated electronic diagnostics use the following procedures to advance the filter through the recharge cycles to check operation. Remove the top cover faceplate assembly by unlock- ing the tabs and lifting, to observe cam and switch operation during valve rotation (see figure 28). 1. P...

  • Page 15

    15 ecowater s y s t e m s troubleshooting (continued) resetting to factory defaults to reset the electronic controller to its factory default for all settings (time, days between recharges, etc.): 1. Press the select button and hold it until the dis- play changes twice to show “code” and the flash- ...

  • Page 16

    16 ecowater s y s t e m s troubleshooting guide & wiring schematic fig. 33 no 24vdc valve motor position switch nc transformer back of electronic controller (pwa) ac in position/ turbine motor auxiliary output j4 24vac 240vac 60hz wiring schematic troubleshooting guide problem cause correction iron ...

  • Page 17

    17 ecowater s y s t e m s repair parts key no. Part no. Description 1 7210478 top cover 2 7275907 transformer, 120 v to 24 v, 10 va 3 7259927 wire harness 4 7336363 repl. Electronic controller (pwa) 5 7210509 faceplate (order decal below) ¢ 7308970 decal, faceplate 6 7211173 support, faceplate 7 727...

  • Page 18

    18 ecowater s y s t e m s repair parts 50 93 92 91 90 89 78 79 77 75 76 wear strip seal cross-section view 63 66 67 62 61 60 59 58 57 56 55 54 70 73 72 73 74 94 51 52 53 64 68 69 65 82 assembled view flow plug assembly 70 80 81 88 87 86 85 84 83 valve exploded view 71.

  • Page 19

    19 ecowater s y s t e m s repair parts key no. Part no. Description 50 7224087 screw, #8-32 x 1” (2 req.) 51 7286039 motor (incl. 2 ea. Of key no. 50) 52 7231393 motor plate 53 0900857 screw, #6-20 x 3/8” (3 req.) 54 7171250 bearing 55 7335024 cam & gear 56 7169180 clip, drain 57 7172793 drain hose ...

  • Page 20

    20 ecowater s y s t e m s warranty limited warranty ecowater systems llc advantage warranty series etf aiv water system congratulations! You have just purchased the highest quality water conditioning product on the market. To register your war- ranty, complete the enclosed warranty registration card...