EcoWater ETF2100 PF Owner's Manual - page 12
3
12
Programming Face Plate Timer
ECOWATER
S Y S T E
M S
The default settings for fill (0 minutes), brine draw (0
minutes), backwash (25 minutes) and fast rinse (5
minutes) cycles of regeneration are factory set for
maximum performance of the filter. Use the following
procedures to check for correct cycle times, or to
change if desired. However, only trained technicians
should change the time settings.
ADJUSTABLE FILL -- Press and hold the SELECT
button until the display shows “000----”, then press
the SELECT button once to advance to the Fill time
adjust screen.
Using the UP or DOWN buttons, adjust the fill time
from 0 minutes to 99:59 minutes.
ADJUSTABLE BRINE DRAW -- Press and hold the
SELECT button until the display shows “000----”,
then press the SELECT button twice to advance to
the Brine Draw time adjust screen.
Using the UP or DOWN buttons, adjust the brine
draw time from 0 minutes to 255 minutes.
12 OR 24 HOUR CLOCK -- The electronic controller
has been factory preset to display a 12 hour clock
(AM / PM). If you prefer, you may change this to
display a 24 hour clock. Press and hold the SELECT
button until the display shows “000----”, then press
the SELECT button three times to advance to the
“12 hr” or “24 hr” time format screen.
Using the UP or DOWN buttons, set the time format
to 12 or 24 hours.
ADJUSTABLE BACKWASH -- Press and hold the
SELECT button until the display shows “000----”,
then press the SELECT button four times to ad-
vance to the Backwash time adjust screen.
Using the UP or DOWN buttons, adjust the back-
wash time from 0 minutes to 99 minutes.
ADJUSTABLE FAST RINSE -- Press and hold the
SELECT button until the display shows “000----”,
then press the SELECT button five times to advance
to the Fast Rinse time adjust screen.
Using the UP or DOWN buttons, adjust the fast rinse
time from 0 minutes to 99 minutes.
TIMER “POWER--OUTAGE MEMORY” -- If electri-
cal power to the timer is interrupted, the “memory”
built into timer circuitry keeps time settings for 6
hours (minimum) or more. The display is blank and
the filter will not regenerate. When electrical power
comes on, one of two things will happen.
1. The present time of day will show steady, meaning
the timer memory has kept all settings.
2. The display will show a time, but it will be flashing.
The timer memory did not keep the time setting and
it must be reset (page 10). If you do not reset the time
setting, regenerations will most likely be at the wrong
time of day.
NOTE: The flashing display is to remind you to reset
the timer.
NOTE: If the filter was in a backwash when power
was lost, it will now finish the cycle.