Eddystone xa500 series Installation And Operaion Manual - page 19
Print Date 31/08/11 Page 19 of 22 E2136-00MA-02
Reverted Output Data Block
(15 extra bytes reverted in response to
# ? 0 sequence)
Title
Status
Possible Values
(ASCII)
Op_Data1
Output data status request byte
third byte echo
fixed at ASCII 0
Op_Data2
Output Forward Power Level MSB (W)
Op_Data3
Output Forward Power Level MSB-1 (W)
Op_Data4
Output Forward Power Level LSB+1 (W)
Op_Data5
Output Forward Power Level LSB (W)
Op_Data6
Output Reverse Power Level MSB (W)
Op_Data7
Output Reverse Power Level MSB-1 (W)
Op_Data8
Output Reverse Power Level LSB (W)
Op_Data9
Output Temperature Level MSB (deg.C)
Op_Data10
Output Temperature Level MSB-1 (deg.C)
Op_Data11
Output Temperature Level LSB (deg.C)
Op_Data12
Output OS number MSB
Op_Data13
Output OS number MSB-1
Op_Data14
Output OS number LSB
- (minus)
. (decimal point)
Null (blank)
0 to 9 (inc)
or X
Op_Data15
Output Amplifier Type
; (1000W)
= (150W)
> (300W)
or X
Op_Data16
Output data 8 bit EOR checksum (of 2-15
inc. only)
Reverted Amplifier Data Block
(15 extra bytes reverted in response to
# ? Y sequence)
Title
Status
Possible Values
(ASCII)
Amp_Data1
Amplifier data status request byte
third byte echo
fixed at Y
Amp_Data2
Amplifier system normal status
N O X
Amp_Data3
Amplifier forward power status
N L F X
Amp_Data4
Amplifier reverse power status
N H X
Amp_Data5
Amplifier heatsink temperature
N H X
Amp_Data6
Amplifier fans status
N F X
Amp_Data7
Amplifier DC supply status
N F X
Amp_Data8
Amplifier current status
N H X
Amp_Data9
Amplifier Current Level MSB (Amps)
Amp_Data10
Amplifier Current Level LSB (Amps)
Null (blank)
0 to 9 (inc) or X
Amp_Data11
Spare
Amp_Data12
Spare
Amp_Data13
Amplifier Ext. Mute start/mute status
S M X
Amp_Data14
Amplifier Interlock start/mute status
S M X
Amp_Data15
Amplifier Power Control int/ext status
I V X
Amp_Data16
Amplifier status 8 bit EOR checksum (of
2-15 inc. only)