EMOTION Optimus 170 Premium left Operating And Installation Instructions

Summary of Optimus 170 Premium left

  • Page 1

    1 optimus 170 premium left operating and installation instructions is there a problem with your product or do you have any questions? Please feel free to contact our hotline: 020 - 8528 1729.

  • Page 2: Index

    2 index accessories and sketch 3 safety instructions 4 part names 5 operating the touch displays 6 whirlpool control 7-10 dry-running protection and settings 10-11 heating and secondary drying 11-12 electrical connection and installation mounting 12-15 care and maintenance 16 required installation t...

  • Page 3

    3 ladies and gentlemen, thank you for choosing our product. For safety reasons, please take some time to read this manual before installing and starting up carefully. Please open the packaging with suitable tools. Accessories and sketch: 1 x waterfall faucet and gasket 1 x hand shower and hand showe...

  • Page 4

    4.

  • Page 5: Safety Instructions

    5 safety instructions 1. Children and people who require care should not bathe without supervision. Persons with heart problems, high blood pressure or diabetes, and other serious illnesses should use the spa with increased caution or after consulting a physician. 2. Persons with heart problems or h...

  • Page 6: Part Names

    6 part names 1. Overflow 2. Outflow 3. Side jets 4. Touch display 5. Air injection vent 6. Suction 7. Ground air nozzles 8. Back jets 9. Headrest 10. Waterfall faucet 11. Hot water 12. Changeover switch 13. Cold water 14. Hand shower.

  • Page 7: Using The Touch Screen

    7 using the touch screen 1. Air nozzles 2. Water jets (large jet) 3. Led light therapy.

  • Page 8: Whirlpool Control

    8 whirlpool control type 230 8014b-s03 rudolf koller gmbh type 230 8014b-s03 rudolf-koller-straße 1 112 rev.2 a-3902 vitis ing. Aigner a tel. +43/2841/8207 fax. +43/2841/8221 email: office.Vitis.At@rkoller.Com technical changes and printing errors reserved!.

  • Page 9

    9.

  • Page 10

    10

  • Page 11

    11 1 general this control has four outlets. Outlet heating (16) is for heating, outlet lamp (15) is for the transformer of the lamp and outlet pump (14) is designated for the pump. Outlet fan (12) is designated for connection of a fan that is only switched on and off. This outlet cannot be regulated...

  • Page 12

    12 3 description of the status indicator for switches with edge illumination if a switch with edge illumination is used, the configuration connector “side led” can be connected for the edge illumination. The side leds of the switch are then illuminated when the water level is adequate (hight of tls ...

  • Page 13

    13 connection description black +12v dc max. 50ma blue gnd brown signal output l-level = water present h-level = water not present 6 settings 6.1 interval adjustment the interval can be adjusted with the sdip-switch s4 (see diagram position 1). When in interval mode, the units are switched “on” and ...

  • Page 14

    14 8 description of the dryer automatic drying the dip-switch s3 (see diagram position 1) must be in the “on” position in order to activate this function automatically after each time the tub is used. If the water in the tub reaches the filling level (tls-hight) the drying function will be activated...

  • Page 15

    15 • wire stripping length of the cable ends: 6mm • when conductors made of thin wires are used, ferrules may be used in conjunction • the protective ground conductor is to be held long enough, that it is pulled out of the terminal after the main wire when failure of the strain relief occurs • only ...

  • Page 16

    16 austria Öve-en 1, part 4 paragraph 49/1980 or, if applicable, 1996 all electric components must be installed in such a way, that persons in the bathroom will only be able to access parts with safety extra-low voltage of 12v. Care must also be taken that electrical installations are set-up, mounte...

  • Page 17

    17 installation instructions installation of water connections (before initial use): 1. Secure the hand shower and the waterfall and connect them to the fitting. 2. Connect the hot tub to your water connections. 3. Connect the drain pipe to your sewer connection. First activation (before final assem...

  • Page 18

    18 care and maintenance 1. For the daily cleaning of the tub, use a soft cloth and regular household detergent. Please avoid cleaners that contain acetone or ammonia. For disinfection, never use formic acid- or formaldehyde-containing agents. The automatic ozone disinfection kills germs and bacteria...