8 Description of the dryer
automatic drying
The DIP-switch S3 (see diagram position 1) must be in the “ON” position in order to activate
this function automatically after each time the tub is used. If the water in the tub reaches
the filling level (TLS-hight) the drying function will be activated after 30 seconds. Regardless
of the time period of usage of the tub, the the drying function will remain in a waiting state.
manual drying
If the DIP-switch is in the “OFF” position, the function can only be activated manually
through the switch. Keep the switch
pressed until the blinking control display (LED)
switches to constant illumination (protection from accidental operation – child safety).
Regardless of the time period of usage of the tub, the the drying function will remain in a
waiting state.
In order to cancel the function the
switch is to be operated once. The function can only
be cancelled when the tub is empty.
8.1 Drying
When the function is activated, the fan is switched on for 3 minutes, 20 minutes after the
dry-running protection sensor TLS no longer registers any water (after the tub has been
emptied).
9 Connection and electronic installation
The connection, the installation of the electronic components, as well adjustments, may only
be carried out by qualified electricians, or under their leadership and responsibility (by an
electric-installation business authorised for such work).
Notice: If work is to be carried out on the water installation, the entire controller must be
switched of and disconnected safely from the power grid (disconnect from the mains for 30
minute)
In order to connect to the network, only a cable of the type H05VV-F3G1,5 (medium PVC
tube cable, YMM-J 3x1,5 mm
2
may be used or H05VV-F3G2,5 (YMM-J 3x2,5 mm
2
).
The following must be observed when carrying out the connection:
•
Only work in a state of no voltage