Connections
Connecting the Trigger Input and Trigger output
The Trigger Input accepts a 12 VDC (nominal) trigger signal from another device via a standard
1/8” mono plug. When the trigger is asserted, the SA-250 will switch On; when the trigger
is removed, the SA-250 will return to Standby mode. The Trigger Output sends out 12 VDC
whenever the main power to the SA-250 is On (and NOT when the SA-250 is in Standby mode)
which can be used to switch on other units with trigger capabilities.