Empire Comfort Systems VFSM-18-3 Installation Instructions And Owner's Manual

Manual is about: Empire Comfort Systems Inc. The White Mountain Vent-Free Burner INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL VFSV-16-3 VFSV-18-3 VFSV-24-3 VFSV-30-3 VFSR-16-3 VFSR-18-3 VFSR-24-3 VFSR-30-3

Summary of VFSM-18-3

  • Page 1

    Installation instructions and owner's manual vented/vent-free burner this is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventila- tion air must be provided. Refer to page 9. Warning: if not installed, operated and ...

  • Page 2: Table Of Contents

    26333-3-1210 page 2 section page important safety information ......................................................................................................... 3 safety information for users of lp gas .......................................................................................... ...

  • Page 3: Warning

    26333-3-1210 page 3 when used without adequate combustion and ventilation air, heater may give off carbon monoxide, an odorless, poisonous gas. Do not install heater until all necessary provisions are made for combustion and ventilation air. Consult the written instructions provided with the heater ...

  • Page 4

    26333-3-1210 page 4 some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to dete...

  • Page 5: Requirements For Canada

    26333-3-1210 page 5 requirements for canada this unit cannot be installed in a unvented application, this unit can only be installed as a vented application with these requirements. Important safety information this unit complies with ansi z21.60and cga 2.26 decora- tive gas appliances for installat...

  • Page 6: Introduction

    26333-3-1210 page 6 attention: during initial use of log you will detect an odor as the log is cured. Notice: during initial firing of this unit, its paint will bake out, and smoke will occur. To prevent triggering of smoke alarms, ventilate the room in which the unit is installed. Warning this appl...

  • Page 7: Product Specification

    26333-3-1210 page 7 product specification product specification natural gas propane gas variable millivolt manual variable millivolt manual regulator pressure setting 3.5" w.C. 3.5" w.C. 6.0" w.C. 10.0" w.C. 10.0" w.C. 10.0" w.C. Gas inlet pressure max. 10.5" w.C. 10.5" w.C. 10.5" w.C. 13.0" w.C. 13...

  • Page 8: General Information

    26333-3-1210 page 8 this is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Keep room area clear and free from combustible materials, gasoline and other flammable vapors and liquids. U...

  • Page 9: Clearances

    26333-3-1210 page 9 h w l 1 l 2 fireplace divider example of large room with 1/2 wall divider. Figure 1 the following formula can be used to determine the maximum heater rating per the definition of unconfined space: btu/hr = (l 1 + l 2 )ft x (w)ft x (h)ft x 1000 50 if the area in which the heater m...

  • Page 10: Clearances (Continued)

    26333-3-1210 page 10 mantel clearances with hood (figure 5) you must have non-combustible materials above the fireplace opening. Non-combustible material must extend at least 8" above fireplace opening. With sheet metal, you must have non-combustible material behind it. Heat resistant materials such...

  • Page 11: Combustible Material

    26333-3-1210 page 11 for masonry built fireplaces free opening area of chimney damper for venting combustion products from decorative appliances for installation in solid fuel burning fireplaces • turn off gas supply to fireplace or firebox. • have the fireplace floor and chimney professionally clea...

  • Page 12

    26333-3-1210 page 12 notice: (damper clamp installation) when installing your log set as a vented installation the damper clamp must be used. When installing your log set as a vent-free installation the damper clamp can be used to eliminate the potential for odors when burning the logs for the first...

  • Page 13: Gas Supply

    26333-3-1210 page 13 check all local codes for requirements, especially for the size and type of gas supply line required. Notice : never use plastic pipe. Check to confirm whether your local codes allow copper tubing or galvanized. Notice : since some municipalities have additional local codes, it ...

  • Page 14

    26333-3-1210 page 14 refer to parts list, page 21 to order loose material (rock wool). Placing lava rock in front of burner on fireplace floor spread lava rocks on fireplace floor in front of the burner pan. The lava rocks are for decorative effect and are not required for fireplace operation. Atten...

  • Page 15

    26333-3-1210 page 15 notice: for easy access to valve for lighting pilot, remove branch log and middle log from burner assembly before lighting. 1. Stop! Read the safety information label. 2. Make sure the manual shutoff valve is fully open. 3. This gas log set is equipped with an ignition device (p...

  • Page 16

    26333-3-1210 page 16 a. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. Before lighting smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the...

  • Page 17

    26333-3-1210 page 17 1. Stop! Read the safety information. 2. Make sure the manual shutoff valve is fully open. 3. This heater is equipped with an ignition device (piezo) which automatically lights the pilot. 4. Refer to figure 15 for the location of the piezo ignitor and control knob. Push in gas c...

  • Page 18: Pilot Flame Characteristics

    26333-3-1210 page 18 figures 16 and 19 show a correct pilot flame pattern. The correct flame will be blue and will extend beyond the thermocouple. The flame will surround the thermocouple just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet. Figures 17...

  • Page 19: Cleaning And Servicing

    26333-3-1210 page 19 annual inspection and cleaning by your dealer or qualified service technician is recommended to prevent malfunction and/or sooting. Turn off heater and allow to cool before cleaning. Remove logs, handling carefully by holding gently at each end. Gloves are recommended to prevent...

  • Page 20: Wiring

    26333-3-1210 page 20 thermostats are not approved on vented decorative appliances. Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. 16", 18", 24" and 30" gas logs (millivolt) thermopile ...

  • Page 21: Troubleshooting

    26333-3-1210 page 21 if the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backfire when lit. If the gas quality or pressure is low, contact your local gas supplier immediately. 1. When ignitor button is pressed, there is no spark at ods/ pilot. A. I...

  • Page 22: Parts List

    26333-3-1210 page 22 attention: when ordering parts, it is very important that part number and description of part coincide. Use only manufacturer's replacement parts. Use of any other parts could cause injury or death. Parts list index no. Part no. Description common parts 1 15425 rear log support ...

  • Page 23: Parts View

    26333-3-1210 page 23 20 21 parts view.

  • Page 24: How To Order Repair Parts

    26333-3-1210 page 24 to order parts under warranty, please contact your local empire dealer. See the dealer locator at www.Empirecomfort. Com. To provide warranty service, your dealer will need your name and address, purchase date and serial number, and the nature of the problem with the unit. To or...

  • Page 25: Appliance Service History

    26333-3-1210 page 25 appliance service history date dealer name service technician name service performed/notes.

  • Page 26: Appliance Service History

    26333-3-1210 page 26 appliance service history date dealer name service technician name service performed/notes.

  • Page 27: Appliance Service History

    26333-3-1210 page 27 appliance service history date dealer name service technician name service performed/notes.

  • Page 28: Empire

    26333-3-1210 page 28 empire empire comfort systems empire comfort systems inc. 918 freeburg ave. Belleville, il 62220 if you have a general question about our products, please e-mail us at info@empirecomfort.Com. If you have a service or repair question, please contact your dealer. Www.Empirecomfort...