  • Page 1

    Installation instructions and owner's manual unvented gas log heater or vented decorative appliance models vented/vent-free burner this is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provide...

  • Page 2: Table Of Contents

    25735-0-0309 page 2 section page important safety information .........................................................................................................................3 safety information for users of lp gas ...............................................................................

  • Page 3: Warning

    25735-0-0309 page 3 warning when used without adequate combustion and ventilation air, heater may give off carbon monoxide, an odorless, poisonous gas. Do not install heater until all necessary provisions are made for combustion and ventilation air. Consult the written instructions provided with the...

  • Page 4

    25735-0-0309 page 4 some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to dete...

  • Page 5: Requirements For Canada

    25735-0-0309 page 5 requirements for canada this unit cannot be installed in a unvented application, this unit can only be installed as a vented application with these requirements. Important safety information this unit complies with ansi z21.60and cga 2.26 decorative gas appliances for installatio...

  • Page 6: Introduction

    25735-0-0309 page 6 attention: during initial use of log you will detect an odor as the log is cured. Notice: during initial firing of this unit, its paint will bake out, and smoke will occur. To prevent triggering of smoke alarms, ventilate the room in which the unit is installed. Warning: this app...

  • Page 7: General Information

    25735-0-0309 page 7 this is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Keep room area clear and free from combustible materials, gasoline and other flammable vapors and liquids. U...

  • Page 8: Clearances

    25735-0-0309 page 8 minimum dimensions for solid fuel burning fireplaces ul127 factory built fireplaces (figure 2) model a b c d vfsv-16 18" 11 1/2" 24" 18" vfsr-16 18" 11 1/2" 24" 18" vfsv-18 17" 14" 28" 17" vfsr-18 17" 14" 28" 17" vfsm-18 21" 14" 32" 17" vfsv-24 23" 14" 30" 18" vfsr-24 23" 14" 30"...

  • Page 9: Clearances (Continued)

    25735-0-0309 page 9 mantel clearances with hood (figure 5) you must have non-combustible materials above the fireplace opening. Non-combustible material must extend at least 8" above fireplace opening. With sheet metal, you must have non-combustible material behind it. Heat resistant materials such ...

  • Page 10: Combustible Material

    25735-0-0309 page 10 for masonry built fireplaces free opening area of chimney damper for venting combustion products from decorative apppliances for installation in solid fuel burning fireplaces • turn off gas supply to fireplace or firebox. • have the fireplace floor and chimney professionally cle...

  • Page 11

    25735-0-0309 page 11 notice: (damper clamp installation) when installing your log set as a vented installation the damper clamp must be used. When installing your log set as a vent-free installation the damper clamp can be used to eliminate the potential for odors when burning the logs for the first...

  • Page 12: Gas Supply

    25735-0-0309 page 12 check all local codes for requirements, especially for the size and type of gas supply line required. Note: never use plastic pipe. Check to confirm whether your local codes allow copper tubing or galvanized. Note: since some municipalities have additional local codes, it is alw...

  • Page 13

    25735-0-0309 page 13 refer to parts list, page 21 to order loose material (rock wool). Placing lava rock in front of burner on fireplace floor spread lava rocks on fireplace floor in front of the burner pan. The lava rocks are for decorative effect and are not required for fireplace operation. Atten...

  • Page 14: Lighting Instructions

    25735-0-0309 page 14 hi/lo regulator control knob piezo ignitor for your safety read before lighting warning: if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted ...

  • Page 15

    25735-0-0309 page 15 to turn off gas to appliance for your safety read before lighting warning: if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When ...

  • Page 16

    25735-0-0309 page 16 lighting instructions 1. Stop! Read the safety information. 2. Make sure the manual shutoff valve is fully open. 3. This heater is equipped with an ignition device (piezo) which automatically lights the pilot. 4. Refer to figure 15 for the location of the piezo ignitor and contr...

  • Page 17

    25735-0-0309 page 17 figures 16 and 19 show a correct pilot flame pattern. The correct flame will be blue and will extend beyond the thermocouple. The flame will surround the thermocouple just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet. Figures 17...

  • Page 18: Cleaning And Servicing

    25735-0-0309 page 18 annual inspection and cleaning by your dealer or qualified service technician is recommended to prevent malfunction and/or sooting. Turn off heater and allow to cool before cleaning. Remove logs, handling carefully by holding gently at each end. Gloves are recommended to prevent...

  • Page 19: Wiring

    25735-0-0309 page 19 thermostats are not approved on vented decorative appliances. Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. 16", 18", 24" and 30" gas logs (millivolt) thermopile ...

  • Page 20: Troubleshooting

    25735-0-0309 page 20 if the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backfire when lit. If the gas quality or pressure is low, contact your local gas supplier immediately. 1. When ignitor button is pressed, there is no spark at ods/ pilot. A. I...

  • Page 21: Parts List

    25735-0-0309 page 21 attention: when ordering parts, it is very important that part number and description of part coincide. Use only manufacturer's replacement parts. Use of any other parts could cause injury or death. Index no. Part no. Description common parts 1 15425 rear log support (vfs(m,r,v)...

  • Page 22: Parts View

    25735-0-0309 page 22 parts view.

  • Page 23: How To Order Repair Parts

    25735-0-0309 page 23 to order parts under warranty, please contact your local empire dealer. See the dealer locator at www.Empirecomfort.Com. To provide warranty service, your dealer will need your name and address, purchase date and serial number, and the nature of the problem with the unit. To ord...

  • Page 24: Empire

    25735-0-0309 page 24 empire empire comfort systems empire comfort systems inc. 918 freeburg ave. Belleville, il 62220 if you have a general question about our products, please e-mail us at info@empirecomfort.Com. If you have a service or repair question, please contact your dealer. Www.Empirecomfort...