EZ Smart 606 User Manual
P. 1
Table of Contents
Introduction
..........................................................................................................................
About the Product
.............................................................................................................
About the
EZ Smart-606
Meter....................................................................................
About the
EZ Smart-606
Test Strips..............................................................................
About the
EZ Smart-606
Test Strip vial..........................................................................
About the Glucode Chip.........................................................................................
Installing/Replacing the battery.....................................................................................
Setting up the Meter
............................................................................................................
Coding your
EZ Smart-606
Meter...........................................................................................
The Control Solution Test
...........................................................................................................
Testing your Blood Glucose Level
...........................................................................................
Preparing the Test Strip...................................................................................................
Obtaining a blood sample....................................................................................
Applying blood sample to the
EZ Smart-606
Test Strip.........................................................
Memory Features
..............................................................................................................
Care and Storage
.............................................................................................................
Display Messages
.........................................................................................................
Specifications
....................................................................................................
Limitations of the Procedure...........................................................................................
Service and Warranty
.......................................................................................................
Customer Service
............................................................................................................................
2
2
3
4
5
5
6
6
7
8
10
10
11
11
13
14
15
20
21
22
23
P. 2
About the Product
Your
EZ Smart-606
System is made up of several components. This booklet is designed to guide
you through the operation of the system with detailed directions and pictures.
Introduction
Congratulations on choosing the
EZ Smart-606
System, the latest advancement in biosensor
technology. Adopted for its ease of use and quick response time, the
EZ
Smart-606
has the ability
to process accurate results utilizing only a small volume of blood for
in vitro
diagnostics. The
EZ
Smart-606
Systems intended use is to provide a convenient and safe monitoring system for
diabetic individuals. This is an over the counter(OTC) product.
Technically, blood glucose is oxidized enzymatically when the electrical current generated by
glucose oxidation is measured. The advantage of using the System comes from the
EZ Smart-
606
Test Strips, which is specially designed to allow the monitoring of your blood glucose level
quickly and easily. What makes the
EZ Smart
-606
Test Strip so special is on how blood samples
are drawn. Our unique design allows you to use a small amount of blood to produce results in only
a short time.
Your EZ Smart-606 System contains:
v
EZ Smart-
606
Meter
v
One vial of
EZ Smart-
606
Test Strips (10 strips)
v
One Glucode Chip (outside the strip vial)
v
One Lancing Device (Optional for compact kit)
v
Ten Lancets (Optional for compact kit)
v
One carrying case
v
v
Log book (Optional for compact kit)
v
Quick Reference Guide
v
One vial of Control Solution (Optional for
compact kit)
Note: 25, 50 test strips vial can be purchased individually.
P. 3
About the EZ Smart-606 Meter
5
2
The FRONT
1
2
3
4
8
9
6
7
1.
Display
Your test results are displayed here.
The large, easy to
read screen guides you
through the test by using num bers and
symbols.
2.
M Button
3.
S Button
4.
Test port
This is where you insert the Test
Strip into the Meter.
The BACK
5
5.
Battery Cover
6.
Unit Switch
Switch for mmol/l or mg/dL.
7.
Label
8.
Reset Button
Press this button to re-set
the system.
9.
Glucode Chip
Insert the Glucode Chip for
coding.
P. 4
About the EZ Smart-606 Test Strip
1
2
3
1
The
EZ
Smart-606
Test Strip is used to perform the blood glucose test in conjunction with the
EZ
Smart-606
Meter.
Each strip can be used only once.
The
EZ
Smart-606
Test Strip consists of the following parts:
1.
Confirmation Window
This is where you can confirm that enough blood has been applied to
the target area.
2.
Target Area
This is where blood is drawn into the
EZ
Smart-606
Test Strip.
3.
Contact Bar
This end of the
EZ
Smart-606
Test Strip is inserted into the Test Port to activate the
EZ Smart-606
Meter. (white side face up)
3
P. 5
About the EZ Smart-606 Test Strip Vial
EZ Smart-606
Control Solution Range
Code Number
Exp. Date
Lot Number
About the Glucode Chip
The Glucode Chip is used to ensure that your
EZ Smart-606
Meter provides you with accurate
results. Before performing the blood glucose test or starting a new strip vial, please check your
EZ
Smart-606
Meter with the Glucode Chip to ensure proper performance
(further instructions
for use of the Glucode Chip is provided on page 7).
After checking your Meter, the Glucode Chip
is also used to code setting.
CODE Number
v
Note: Always use the Glucode Chip to ensure your
EZ Smart-606
Meter is performing properly.
v
DO NOT
misplace your Glucode Chip.
P. 6
Installing/Replacing the battery
The
EZ
Smart-606
Meter uses one 3-Volt lithium battery (CR-2032).
When to Replace
the
Battery
When the battery is low, the Meter will show a warning signal. When this
display appears, it is time to replace a new battery. When the low battery
warning signal is shown, the
EZ Smart-606
Meter will provide accurate results
for approximately 50 more measurements.
How to Replace
the Battery
1.
From the back of the Meter, gently slide and remove the battery cover.
2.
Insert a 3-Volt lithium battery (CR-2032) with the + side facing up.
3.
Slide battery cover back into place.
Setting Up the Meter
To turn the Meter on, first pull the plastic tab out from the battery chamber, then press the reset button
located at the back of the Meter and proceed with the following instructions.
1.
Select unit, mg/dL or mmol/l on the back.
Code Setting and Unit Selection
2.
Plug the Glucode Chip into the Glucode Chip slot for strip coding.
P. 7
Coding your EZ Smart-606 Meter
Each batch of
EZ
Smart-606
Test Strip is encoded with a number that must match one of the code
numbers stored in the
EZ Smart-606
Meter. In order to ensure an accurate result, the code number
on the display must also match the code number found on the
EZ
Smart-606
Test Strip vial.
1.
Insert the
EZ Smart-606
Glucode Chip into the Glucode Chip slot.
The
EZ
Smart-606
Meter will automatically be encoded.
Note: Code the
EZ Smart-606
Meter whenever you start a new
Test Strip vial.
2.
All segments of the LCD display will appear indicating that the
EZ
Smart-606
Meter is functioning properly. Then a beep will sound,
followed by the code number.
3.
Match the code number on the
EZ
Smart-606
Meter display with
the code number on the
EZ
Smart-606
Test Strip vial. If the code
matches, you may begin to test.
P. 8
The Control Solution Test
The Control Solution is used to check and ensure that the
EZ Smart-606
Meter and
EZ
Smart-606
Test Strip are working together properly and that you are performing the test correctly. For an
accurate reading, check the system with the
EZ
Smart-606
Control Solution on a routine basis
(approximately once a week)
.
NOTE :
1. Control Solutions are required but not supplied.
2. There are three
EZ Smart-606
Control Solutions at different desired range of aqueous
glucose (Low, Normal or High). For more information about the
EZ Smart-606
Control Solution,
Please read your
EZ Smart-606
Control Solution package insert. Two sets of control solution
should be used, a high level and a low level control solution of your choice.
1
. Insert a
EZ
Smart-606
Test Strip,
white side face up, Contact Bars
end first, into the test port. The
EZ
Smart-606
Meter will auto-
matically turn on.
To perform a Control Solution test:
2.
All segments of the LCD dis-
play will appear, indicating
that the
EZ
Smart-606
Meter
is functioning properly.
3.
A beep will sound and the code number will appear followed by a flashing
S
symbol. Be sure the code number on the display matches the code number on the
EZ
Smart-606
Test Strip vial. If the code numbers do not match, code the
EZ
Smart-606
Meter by using Glucode Chip, accordingly.
P. 9
4.
After the
S
symbol appears,
press the M button for 3 sec
to switch the
ctl
symbol. The
ctl
symbol indicates that the Meter will mark your current
test as a Control Solution test. Now you are ready to apply the Control Solution.
5.
Discard the first drop of Control Solution and apply a small drop of Control
Solution onto your fingertip. Then, place this drop of Control Solution onto the
target well area.
6.
As soon as enough solution has been drawn into the Confirmation Window, the
EZ Smart-606
Meter will beep and begin counting down from
8
to
1
and the
Control Solution test result will appear.
Caution:
Please remember that in order to prevent contamination, follow
the above instructions for preforming the Control Solution test.
Results falling outside the specified range may be caused by:
v
Error in performing the test
v
Expired or contaminated Control Solution
v
Expired or contaminated
EZ Smart-606
Test Strips
v
Improper coding of the
EZ Smart-606
Meter
v
EZ Smart-606
Meter malfunction
Comparing Control Solution Results
The
EZ Smart-606
is functioning properly if the result falls inside the specified range printed on the Test
Strip vial. If the test result falls outside the specified range, repeat the test.
Note:
The result will not be stored into the memory and will not be incorporated
into the average in the
ctl
mode.
DO NOT
use the system if the problem persists.
Please call Tyson Bioresearch, Inc., Customer Services
at
+886-37-585-998 or website of www.tysonbio.com
P. 10
Testing your Blood Glucose Level
Before testing blood glucose, you need the following items:
1.
EZ
Smart-606
Meter
2.
EZ
Smart-606
Test Strip
3.
Adjustable Automatic Lancing Device
4.
Sterile Lancet
5.
Glucode Chip
v
Never
share a lancing device and lancet with another person.
v
Always
use a new and sterile lancet. Lancets are for single use only.
v
Always
use a new
EZ
Smart-606
Test Strip. Test Strips are for single use only.
v
Do not
get lotion, oil, dirt or debris in or on the lancet and lancing device.
Caution:
To reduce the chances of infection:
Preparing the Test Strip
1.Wash hands using
soap and warm
water.Rinse and
dry thoroughly.
2.
Pull out an
EZ
Smart-606
Test
Strip from the vial
and re-cap the
vial immediately.
3.
Insert the Test
Strip white side
face up, into the
test port.
4.
A beep will sound and the code number will appear followed by a flashing
S
symbol. Now you are ready to obtain a blood sample.
Reminder:
Make sure that the code number on the display matches the code
number displayed on the Test Strip vial. If the code number on the display does
not match the code number on the Test Strip vial, code the Meter by using
Glucode Chip, accordingly.(
See page 7
)
P. 11
Obtaining a Blood Sample
SAMPLE MAY BE OBTAINED FROM FINGER
For further instructions please see the insert provided with lancing device.
1.
Unscrew and remove the endcap of lancing device.
2.
Insert the lancet into the lancet holder.
3.
Twist and remove the protective lancet cover to expose the sterile needle tip.
4.
Recapping and unscrewing the endcap to the body of the lancing device.
5.
Pull back on the cocking mechanism until it comes to a stop.
6.
Place the lancing device firmly against the finger tip and press the release button.
PERFORM THE TEST
7.
After sampling, remove the endcap containing the used lancet carefully.
8.
Remove the lancet from the lancing device. Discard the used lancet properly in accordance with
local, state, and federal law.
Applying blood sample to the EZ Smart-606 Test Strip
1.
After obtaining a blood
sample, place the drop onto
the test well of
the
EZ Smart-
606
Test
Strip.
2.
Blood is automatically
drawn into the
EZ
Smart-
606
Test Strip.